Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A103 FIREPROOFING AND GENERAL DETAILS.PDF
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CA R M E L C I T Y C E N T E R Ca r m e l , I n d i a n a Bu i l d i n g A Pe n t h o u s e I n t e r i o r s COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 A103 FIREPROOFING AND GENERAL DETAILS Bid Set ##/##/#### THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL ANDUNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2011JAMES R. STUTZMAN, AIA, Carmel, Indiana. SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A ROUGH-IN DIMENSION 2 1/2" METAL STUD @ DEMISING W/ 2 1/2" FG INSULATION. 5/8" DRYWALL TO DECK ABOVE. 5/8" SHEATHING @ TUB FLANGE. SOUND INSULATION MEMBRANE. TUB OR SHOWER SEE PLAN SEE PLAN 0' MOUNTING BRACKET. MOUNTING BRACKET. CLEAR SHOWER GLASS. PROVIDE PARTIAL HEIGHT SHOWER DOOR. SLOPE 1/4":1'-0". EDGE OF BULLNOSE TILE BEYOND. CONTINUOUS WOOD BLOCKING MOISTURE - MOLD RESISTANT GYPSUM BOARD MODELNUMBERTRADENAMEPRODUCTMATERIAL SHOWER RECEPTOR SOUND INSULATION MEMBRANE 4" CROWN MOLDING SEE PLAN CERAMIC TILE. MOISTURE - MOLD RESISTANT BOARDMOISURE - MOLD RESISTANT BOARD @ TILE. CERAMIC TILE. BATHTUB SHOWER MODELNUMBERTRADENAMEPRODUCTMATERIAL SOUND INSULATION MEMBRANE 32 " M A X . 32 " M A X . 38 " M I N . 9" MAX.48" 38 " M I N . 3" MAX.54"3" MAX. 32 " M A X . 38 " M I N . 15"15" 32 " M A X . 6" M A X . 38 " M I N . 38 " M I N . 27" MIN.27" MIN. INDICATES AREAS TO RECEIVE WALL BLOCKING. CENTERLINE BACKWALL HEAD FOOT (CONTROL WALL) NOTE: PROVIDE THE BLOCKING INDICATED ABOVE AS A MINIMUM REQUIREMENT FOR FUTURE GRAB BAR ATTACHMENT. SEE CEILING PLAN VARIES 2'-0 1/2"X2'-0 1/2" R.O. 5/8" TYPE X(GYPSUM BOARD BOTH SIDES) 3 5/8", 20 GA. STUD @ 16" O.C. FIRE CAULK ASSEMBLY 5/8" TYPE X (GYPSUM BOARD BOTH SIDES) 3 5/8", 20 GA. STUD @ 16" O.C. R11 BATT INSULATION AFF (SEE CEILING PLAN) ATTACH PER MANUFACTURE'S REQUIRMENTS SANYO MECH. EQUIPMENT CONCEALED PLENUM NOTE CP1. GYPSUM BOARDCEILING FIRE CAULK ASSEMBLY METAL CHANNEL 3 5/8" METAL FRAMING MILCOR METAL DOOR DWR-MODDEL NO. 3207-030 24"X24" WITH 5/8 GYP. BD. PANEL INSERT. REFER. MANUFACTURES SPECS. 1" 10" MAX. 2-5/8" SFRM 4" 1 1 / 4 " MIN. STEEL BEAM STUD WALL WIDTH VARIES SCREWS (TYP.) #8 WAFERHEAD FRAMING 3.4 EXPANDED METAL LATHATTACHED TO OUTRIGGER NO EXPOSED METAL 0.145"x|4" POWER ACTUATED FASTENER @ 16" O.C. (MAX.) (TYP.)REFERENCE FASTENER MANUFACTURERICBO FOR FASTENER CAPACITY OR PER ENGINEER OF RECORD NO M I N A L JO I N T W I D T H SLOTTED TRACK 25 GA. METAL ANGLE (TYP.) 5/8" DEFLECTION GAP 4" TO 2" x 20 GA. Z-BARS OR 16 GA. CRC @ 16" O.C.(MAX.) DEMISING OR CORRIDOR WALL OFFSET FIRE CAULK ASSEMBLY 1 HR. RATEDWALL, MIN. 2 1/2", 20 GA.STUD 16" O.C. 'T' GRID CEILING RESIDENCE SIDEDEMISING WALL RESIDENCE SIDE DOUBLE LAYEROF 5/8" GYPSUM BOARD 0. 2 3 6 1" 0. 1 9 7 " GYPCRETE STRUCTURAL SLAB BASED ON REGUPOL QT SYSTEM WH I T E BO X (S H E L L & C O R E ) IN T E R I O R IM P R O V E M E N T S QT4005SCU (INTERIOR IMPROVEMENTS QT3006.3W 0. 2 3 6 1" 0. 1 9 7 " GYPCRETE STRUCTURAL SLAB BASED ON REGUPOL QT SYSTEM SINGLE BOTTOM PLATE NON-LOAD BEARING PARTITION AT INTERIOR PARTITIONS WH I T E BO X (S H E L L & C O R E ) IN T E R I O R IM P R O V E M E N T S QT4005SCU (INTERIOR IMPROVEMENTS QT3006.3W 0. 2 3 6 1" 0. 1 9 7 " QT4005SCU (INTERIOR IMPROVEMENTS QT3006.3W GYPCRETE STRUCTURAL SLAB BASED ON REGUPOL QT SYSTEM DOUBLE BOTTOM PLATE AT ALL DEMISING WALLS ISOLATION FILLER AT DEMISING AND SHELL CORRIDOR WALL WH I T E BO X (S H E L L & C O R E ) IN T E R I O R IM P R O V E M E N T S FIRE CAULKASSEMBLY 1 HR. RATED WALL CORRIDOR SIDE 3 5/8", 20 GA.STUD @ 16" O.C. 'T' GRID CEILING CORRIDOR WALL SFRM ON STEEL BEAM 2 1/2", 20 GA. STUD 16" O.C. RESIDENCE SIDE 5/8" TYPE X (GYPSUM BOARD BOTH SIDES) 1 HR. RATED WALL CORRIDOR SIDE 5/8" TYPE X (GYPSUM BOARD BOTH SIDES) 3 5/8", 20 GA.STUD @ 16" O.C. 2 1/2", 20 GA. STUD 16" O.C. 'T' GRID CEILING RESIDENCE SIDE CORRIDOR WALL FIRE CAULKASSEMBLY 4 3/4" 1 HR. RATED WALL CORRIDOR SIDE 5/8" TYPE X (GYPSUM BOARD BOTH SIDES) 3 5/8", 20 GA.STUD @ 16" O.C. 2 1/2", 20 GA. STUD 16" O.C. 'T' GRID CEILING RESIDENCE SIDE CORRIDOR WALL FIRE CAULKASSEMBLY FIRE-RESISTIVEJOINT SPRAY OVER MINERAL WOOL,REFERENCE U.L.SYSTEM #HW-D-0377. MAX. 1 HR. RATEDWALL, MIN. 2 1/2", 20 GA.STUD 16" O.C. 'T' GRID CEILING RESIDENCE SIDEDEMISING WALL RESIDENCE SIDE FIRE CAULKASSEMBLY DOUBLE LAYEROF 5/8" GYPSUM BOARD 4 3/4" 1 HR. RATED WALL, MIN. 2 1/2", 20 GA.STUD 16" O.C. 'T' GRID CEILING RESIDENCE SIDEDEMISING WALL RESIDENCE SIDE DOUBLE LAYEROF 5/8" GYPSUM BOARD FIRE-RESISTIVEJOINT SPRAYOVER MINERAL WOOL,REFERENCE U.L.SYSTEM #HW-D-0377. FIRE CAULKASSEMBLY MAX. VARIES 1 3/4" 1 3 / 4 " VA R I E S A6/A104 B6/A104 5/8" GYP. BD. 3/4" PAINTED POPLAR STOOL WITH 1/8" ROUNDED EDGE 3 1/4" PAINTED POPLAR APRON EXISTING EXT. WALL A B 5/8" GYP. BD. EXISTING EXT. WALL GYPSUM BOARD WINDOW OPENING VARIES 1/4" REVEAL, MIN. VA R I E S A 9/A104 B9/A104 5/8" GYP. BD. 3/4" PAINTED JAMB 3 1/4" PAINTED POPLAR CASING EXISTING EXT. WALL B A FINISHED FLOOR 3 1/4" CASING CL-416 5 1/4" BASE CL-127 NOTE: GENERAL BASE 3 1 / 4 " 3/4" 3 1/4" BASE NOTE: TO BE USED IN CLOSETS, PANTRY, MECHANICAL, UTILITY AREAS SCALE: 1 1/2"= 1'-0" 8 TUB/ SHOWER DEMISING WALLS A103 SCALE: 1 1/2"= 1'-0" 2 INTERIOR ELEVATION AND DETAILS A103 SCALE: 1 1/2"= 1'-0" 1 PENTHOUSE SHOWER/ BATH DETAIL A103 SCALE: 1/2" = 1'-0" 7 BLOCKING REQUIRMENTS A103 SCALE: 1 1/2"= 1'-0" 5 MECHANICAL UNIT PLENUM A103 SCALE: 1 1/2"= 1'-0" 10 FIRE PROOFING DETAIL A103SCALE: 3" = 1'-0" 14 TYPICAL DETAILS A103 SCALE: 3" = 1'-0" 13 TYPICAL DETAILS A103 SCALE: 3" = 1'-0" 12 TYPICAL DETAILS A103 SCALE: 1" = 1'-0" 11 FIRE PROOFING DETAIL A103 SCALE: 3" = 1'-0" 6 WINDOW SILL & JAMB DETAILS A103SCALE: 3" = 1'-0" 9 DOOR JAMB DETAILS A103 SCALE: 3" = 1'-0" 3 WOOD MOULDINGS A103 0 3''6''9'' Bid Set #1.1 10.27.10 10.27.10 LGALGA 11.09.11 11.09.11 BANK SET 11.09.11 BID SET 12.15.11 CA R M E L C I T Y C E N T E R - B U I L D I N G A CO N D O M I N I U M U N I T 6 0 5 72 0 S . R a n g e l i n e R o a d Ca r m e l , I n 4 6 0 3 2