HomeMy WebLinkAbout0201.97 Truss Plans � avis Hc� r� � � , �, L C
R - VALUE DETAIL
OUTSIDE CEILING SURFACE AIR FILM
20 YR. FIBERGLAS SEAL-TAB ROOF SI-IINGLES
15 Ib. ASPNALT FE�T PAPER
7/16" OSB ROO� DECK
INSULATION
4
2 q
5/8" DRYWALL � �
I(�lS�DE CEiI_ING SURFACE AIR F1LM
inside Ceiling Surface Air Film R 0.68
5/8" Drywall R 0.56
Batt Insulation R 38.00
7/16" Roof Deck Sheathing R 0.62
15 Ib. Asphalt Felt Paper R 0.06
Piberglass Roof Shingles R 0.44
Outside Ceiling Surtace Air Film f2 0.17
Typical Ceiling Section Total R -Value R 40.53
TYPICAL CEILING SECTION
SCALF: f,=1`-O' 1{I(�i9?—
1 (
� � VI � � � C� �' � , � �_ �
R - VALUE DETAIL
SECOND
FLOOR EXTERIOR INSULATED
LEVEL SI-IEATI-IING
I/2" DRYWALL
BATT INSULATION EXTERIOR VINYL SIDING
w/ POLYE4-ITYLENE VAPOR BARRIER •
INSIDE WALL SURFACE AIR FILM OUTSIDE WALL SURFACE AIR I
n
z
a
z d
2 q
BATT IvSULATION
w/ POLYENTYLENE VAPOR BARRIER
INSIDE WALL SURFACE AIf2 FILM Inside Nlall Surface Air Fiim R 0.68
1/2" Drywall R 0.45
I/2° DRYWALL —� Batt Insulation R 13.00
FIRST 1/2" Exterio�Sheathing R 3.00
FLOOR
LEVEL Exterior Vinyl Siding R 0.50
Outside Wall Surtace Air Film R 0.17
Typical Wall Section Total R -Value R 17.80
TYPIC�L W.�LL �EC�iG�l
�CALE� I"-I'-O' I/10/9?