HomeMy WebLinkAbout1290.98 Sq. Ft. . �
`�� �°� S �C �HULL � � � R
BUILDING FILE REPORT
Builder's File: YORKS191.BLG Date: October 15 1998 Page 1
Builder Information -
Home Builder Name: DAVIS HOMES
Model Name or Number: YORKSHIRE
Development Name: SHELBORNE VILLAGE
Property Address: LOT 191
Energy Analysis Info
Insulation Contractor Name: Overhead Door Insul. Div.
Telephone Number: (317)842-7444
Building Plan Date: 2/10l98
General Design Characteristics
� House Type: Two Stories
Foundation Type: Siab
Conditioned Floor Area: 1656.00
Number of Bedrooms: 3
Conditioned Floor Area Over Garage: 0.00 % Of Total Floor Area
Heated First Mid Second Third
Basement Level Level Level Levei
Distribution of Cond Floor Area(°!o) 50.0 50.0
I , , Heated First Mid Second Third
iCharacteristics of Each Floor Basement Level Level Levei Level
� Number of Corners` 5 5 �
Percent Open to Floor Above 8.0 0.0
� Nominal Flat Ceiling Height 8.0 8.0 �
Percent Cathedral Ceiling 0.0 0.2
Schuller Intemalional,Inc.Building Insulation Division P.O. Box 5108 Denver,CO 8027 7-5108.
For information on the Pertormance Home Tolal Insulation System,call 1�00.�43103. .
This information does not constitute any wavanty of energy cost or savings. �
REM/Gold�2.33(c)1996 Archttectu2l Energy Corporation,Boultler,CO.
n
BUILDING FILE REPORT
YORKS191.BLG Page 2
Building Envefope Characterisiics
Insulation Level Specify below...
Ceiling(Aitic Above): 38.0
Cathedral Ceiling: 38.0
Rim/Band Joist: 13.0
Frame Wall(Frame Cavity): 13.0
Frame Wali(COntinuous): 5.5
Masonry Wali: 0.0
Foundation Wall(Cavity): 0.0
Foundation Wall(Continous): 11.0
Frame Floor: 19.0
Duct: FLEX DUCT R-5
� Infiitration Rate(ACH): 1.00
Wall Construction Type: Frame
Window Type Double -Vinyl
Window U-Value: 0.46
Window SHGC: 0.57
i Window Area(exciuding fnd walls): 208.0 square feet
Number of Non-Glass Exterior poors: 2
Average Slab Depth Below Grade
IBasement: 0.0
First Level: 1.0
Mechanical Systems Characterislics
Heating System Type: Fuel-fired air distribution
Heating Fuel Type: Gas
Cooling System Type: Air conditioner
Duct Location: Attio-under insul
Domestic Hot Water Fuel Type: Gas
Schuller Intemational,Inc.Building Insulation Division P.O.Box 5108 Demer,CO&YL175108.
For intormation on the Pertortnance Home Total Insulation System,call 7-&70-65A-3103. .
This information dces not constitute eny vrarranty of energy cost or savings. �
REMIGoId v2.33(c)1996 Archiiectural Energy Corporation, Boulder,CO.
4�� �,c� S ( �b�l� � L � L � E � R
1993 MEC OVERALL BUILDING Uo COMPLIANCE
Date: October 15 1998 Building Fiie: YORKS191.BLG
Home Builder: DAVIS HOMES Weather Site: Indianapolis, IN
Model Name or Number: YORKSHIRE Degree Days, H/C: 5653/378
Insulation Contractor: Overhead Door insui. Div. Energy Costs: Indiana Gas
Contractor's Telephone: (317)842-7444
Elements Insulation Levels
1993 MEC As Designed
Roofs/Ceilings(U-Value) 0.028 0.026
Above-Grade Walis (U-Value): 0.131 0.100
Basement Walls (U-Value): 0.088 0.075
OVERALL Uo: 0.101 0.079
This home meets the overall thermal pertormance requiremenis of the 1993 Model Energy Code
based on 5653 heating degree-days. (Section 502, Model Energy Code, 1993 edition).
Building Elements Cavity Ms. Contin. Ins Frame
R-Value R-Value Spacing Uo Area
Roof/Ceilings
Roof 38.0 0.0 24.0" o.c. 0.025 645.8
Roof 38.0 0.0 24.0" o.c. 0.027 192.0
Above=GradeWalls
Wall 13.0 5.5 Wood, 2x4, 16" o.c. 0.054 1757.8
Joist 13.� 0.0 n/a 0.061 125.7
Window n/a n/a n/a 0.460 52.0
Window n!a n/a n/a 0.460 52.0
Window n/a n/a n/a 0.460 104.0
Door n/a 2.0 n/a 0.372 40.0
Basement Walls
Wall 0.0 11.0 None 0.075 125.7
Schuller Intemational,Inc.Building Insulation Division P.O.Box 5109 Denver,CO&Y2175108.
For infortnation on the Pertortnance Home Total Insulation System,call 1-800-�t3103. �
This information does not constitute any wananty of energy cost or savings. �
REM/Gold Y2.33(c)1996 Architectural Energy Corporation,Boulder,CO.