HomeMy WebLinkAbout1323.98 Energy Certificate �� .,
Q�,� '�w�,� S ( H U �. L � �
I �
BUILDING FILE REPORT
Builder's File: PEM813].BLG Date: October 271998 Page 1
Builder inforrnation
Home 8uilder Name: DAVIS HOMES
Model Name or Number: PEMBRIDGE
Development Name: SHELBORNE VILLAGE
Property Address: LOT 131
Energy Analysis Info
Insulation Contractor Name: Overhead Door Insul. Div.
Telephone Number: (317)842-7444
Building Plan Date: 4/13/98
General Design Characteristics
House Type: One Story
Foundation Type: Slab
Conditioned Floor Area: 1804.00
Number of Bedrooms: 3
Conditioned Floor Area Over Garage: 0.00 % Of Total Floor Area
Heated First Mid Second Third
Basement Level Level Level Level
Distribution of Cond Floor Area(%) � I 100.0 �
Heated First Mid Second Third
Charactenstics of Each Floor Basement Level Level Level Level
Number of Comers 10
Percent Open to Floar Above 0.0
Nominal Fiat Ceiiing Height 9.0
Percent Cathedral Ceiling 0.8
RELEASE� FOR COi+!$TRUCt10RE
Sub)aat to aomptiance with all 1@o0ulot{oefg
of 2tsfa nnd �.ocal C�doa
DEPT OF COEd�6JiUidITY SERIVIC�S
CITY OF CA�MIEL i GLAY TOlRiCd�N6P
ItddiAP9A
SchuAer lirtemational,lnc.Buildingdnsulation Division P:O.Box 5106 Denver,CO E0217b108.
For information on the Pertormance Home?otal Insulation System,call 1-800-&543103.
� This information does not constitute any warrantybf�energy cost or savings.
REM/Goltl�2.33(c)1996 ArchitecturehEnergy Corporetion,Boulder,CO.
;�-�
' BUILDING FILE'REPORT
PEMB]31.BLG page 2
Building Envelope Characteristics
Insulation.Level Baseline
Ceiling(Attic Above): 38.b
Cathedral Ceiiing: 38.0
Rim/Band Joist: 13.0
Frame Wall(Frame Cavity): 13.D
Frame Wall(Continuous): 4.4
Masonry Wall: 0.0
Foundation Wall(Cavity): 0.0
Foundation Wali(Continous): 10.0
Frame Fioor: 19:0
Dud: FLEX DUCT R-5
Infillration Rate(ACH): 0.75
Wall Construction Type: Frame
Window Type Double-Vinyl
Window U-Value: 0.46
Window SHGC: 0.57
Window Area(excluding fnd walls): 216.0 square feet
Number of Non-Glass Exterior poors: 2
Average Slab Depth Below Grade
Basement: = 0.0
First Level: 1.0
Mechanical Systems Characteristics
Heating System Type: Fuel-fired air distribution
Heating Fuel Type: Gas
Cooling System Type: Air wnditioner
Duct Location: Attic-under insul
Domestic Hot Wate�Fuel Type: Gas
Schuiler Inlemational, Inc.BuildingJnsulation Division P.O. Box5108 Denver,;C0802775108.
For.information on the Pertormance Home Total Insulation System,call!1�00-654-37IX3.
ThiSinformation does not constitu[e.any warranty of energy.cost or sa'vings.
REM/Gold�/2.33(c)1996 Architedural�Energy Corporatioq�8oulder,CO.
�
t�'
`�� �c� S C H U L L E R
I
1993 MEC OVER.4LL BUILDING Uo COMPLIANCE
Date: October221998 Building File: PEMB131.BLG
Home Builder: DAVIS HOMES Weather Site: Indianapolis, IN
Model Name or Number: PEMBRIDGE Degree Days, H/C: 5653/378
Insulation Contractor: Overhead Door Insul. Div. Energy Costs: Indiana Gas
Contractor's Telephone: (317)842-7444
Elements Insulation Levels
1993 MEC As Designed
� Roofs/Ceilings(U-Value) 0:028 0.026
Above-Grade Wails (U-Value): 0.131 0.113
Basement Walls (U-Value): 0.088 0.081
OVERALL Uo: 0.078 0.069
This home meets the overall thermal performance requirements of the 1993 Model Energy Code
based on 5653 heating degree-days. (Section 502, Model Energy Code, 1993 edition).
Building Elements Cavity Ins. Contin. Ins Frame
R-Value R-Value Spacing Uo Area
Roof/Ceilings
Roof 38.0 0.0 24.0" o.c. 0.025 451.0
Roof 38.0 0.0 24.0"o.c. 0.027 1426.1
Above-GradeWalis
Wall 13.0 4.4 Wood, 2x4, 16" o.c. 0.057 1525.4
Window n/a n/a n/a 0.460 54.0
Window n/a n/a n/a 0.460 54.0
Window n/a n/a n/a 0.460 108.0
Door n/a 2.0 n/a 0.372 40.0
Basement Walls
Wall 0.0 10.0 None 0.081 194.3
Schuller Intemational, Inc:�Building Insulation Division P.O.Box 5108 Denver;CO 802175108.
� For information on the Pertormance Home Total Insulation System,call 1 A0464-3103.
This information does not constRUte any wartanty of energy cost or savings.
� REM/Gold�2.33(c)1996 Architectural Energy Corporetion,Boulder,CO.