Loading...
HomeMy WebLinkAbout05110065-Site PlanSclm~der Cort~raUon ~s~ineerini OUs Avenue Surveyt~ HJstur~ Fort H~u'rinon ~ Arddtecture Indiana 48~1S-103'/ GEl · LIS ~17-8~6-'/100 GeoloSy 'lhb Hot Plan Pl~ F~ R.H. of IndL-~a Lot if 85 , containing 6,599 S.F.±, in Stanford Pork Sect~ f ! IN$1R. J 200500009:85 13683 Stanford Drive (50'R/W) Carmel, Indiana 46074 Prepared Date: 11/0f/05: B~, AMA Prq~311ed J~l]/ll~(s): INVENTORY Community Restrictions: i , Sde Yard =3 min, Rear Yard = N,,/A Aggregate = 6 (RH.) R.H. of Indiana Finished F°ar Elevation Information Pad Grade = 915;4 per pton Pad Grade' + 0.7 = Garage FFE (91§.1) Garage FFE + 1.5' = ,ResJdentinl FFE I917.6) Residential F~ - 9.0 = 8asament FFE Ig08.6) Note.: the garage finished floor devotion is 1.~. a~o~ the curb at the drive, per plan. Plot Plan Le__~.ffi~_ ~ Proposed Grades 000.0 Existing 6rades _----000.0----'"' Contour Grade Approx, Lateral Locatior · ----- Sanitary Sewer Lines Storm Sewer Lines v -- Water Service Lines ...... Sub-S~rface {)rain Lines Uonhole (Sonit. ary Storm) Beehive Inlet (Storm) Curb Inlet (S~erm) . End Section (Storm) A Fire Hydrant ......... Row Line of swale -- Building Line (ElL / BSL) ....... Easement Line ~lote: Sanitary Sewer Top of Casting information Upstream Manhole, TC=915,20 Downstream Monhele~ TC=916.30 per plan. Ground Cover Calculations Drive =513 SF± Public Walk =194 Private Walk = 37 SF:I: Hydrosesding =2,914 SF± Sod =190 SYt , from Resr of residesce T~915.20 .~ER PLAN Note: This drawing is based on construction plans or record drawings, and is not based upon a fldd survey. The Schneider Corporation does not warrant the nccurocy or sufficiency of this infermatiou. Contractors should v~rify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately;, failing to do so results in the contractors assumption of sil liability. Note: The basement elevation, depicted hereon, has been determined and based upon the pad grades and/ar centonrs taken fra'n the constructinn plans for this subdivision. Unless stated, no infon'natlon about fluctuating water table~, soll conditions, ar soil types nas been provided ~ stated on said plans. It is r~cammended that the basement finished floor elevations be at least tea feet (2') above the normal psat elevation of any adjoining bodies of water, unless a study of facts reveals otberwis~. If during the excavation prOCeSS any ~sund water is ~ltnesend, The Sdmeider Comaration should be not~ immediately. The basement elevation should be raised two feet (2') above the Found water, end aclaltkmal constructien techniques should be incorporated to alleviate future problems. Note: Samp pump(s) to be placed by buader as needed. Detail at G~ened/Storm Water flo~ pattem for individual tote. Note: Builder to ensure positive drainage away from sfructure(s). Lot # 85 Vb05.0043842 Assumed North Scale: 39.6' ~ Sidewalk to be placed 1' from property line, 4' [rom back of curb. par plan. Note: Per Carmel zoning ordinance 26.t.1: The residential district limits height to tweaty-flve feet (25'), however a dwdling may be increased in hdght to thirty-five feat (35') provided the side and rear yards are incrensed an additional one that (t') for eaon one font (1') the structure exceeds the first twenty--fl~ feet (25') in height, The contractor is to maintain a minimum distance of t~ feet (10') between the sanitry sewer and ~ater line Ic~teruls. Flood Hazard Statement: The accuracy of any flood hazard ama shown on th~s report is subject to insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard Indiana (maps dated February 19. 2003). ~PLOT PtJ~I--~'CUSTOM~. ~ FLOOD HAZARD STATEMENT CERTIFICATION No. (so o3 Ylllllllllfilltfi~¢