Loading...
HomeMy WebLinkAbout05110020-Site PlanNote: Contractor should vedty sim specific information depicted hereon with the approved construction plans for this development. Note: Minimum Front yard - Vadabts Minimum Between Residences- 6' Minimum Rear Yard - 20' Gar. FFE = 913.9 1st Fir FFE = 915.7 Bsmt FFE = 905,9 Drive Slope = 2.4% BUCKINGHAM - ELEV 6C FULL BSMT - 9' Wails 3 CAR - Side Entry Wd Deck "1" 74 2' HP LOT Cf 11 +19,512 SF PAD 913.6 PER PLAN ~ = Proposed Grade ~ = Drainage Flow XX.X = Existing Grade Flood Hazard Note: Lot Number 11 lies within Zone "X" per the scaled location on the Flood Insurance Rate Maps for Hamilton County. indiana (Communit~ Panel #18057C0205F. dated February 19, 2003). Note: This drawing is base~ upon construction plans and/or record drawings prepared by others and is not based upon a field survey. COOR Consulting & Land Services. Corp. does not warrant the correctness or th[egdty of this information. The contractor/owner should verity existing conditions prior to construction. Any varying field conditions or any discrepancy with the information contained hereon should be immediately reported to COOR Consulting & Land Services, Corp.; failure to do so would result in the contractor/owners assumption of liability. -303 WEST MAIN STREET KNIGHTSTOWN. INDIANA (888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692 ~2004-250.011 REV SONS: I Note: Conc Flatwork Sq. Ft = +1536 Public Walk Sq Ft = +420 Sod Sq Yds = -+336 Seeding Sq Ft = -+12586 The proposed construction grades depicted hereon are based upon nformation, proposed grades and/or contours, taken from the approved construction ptsns prepared for this subdivision. Untess stated hereon, no information pertaining to but not limited to, fluctuafing wa[er table elevations, soil types or conditions within the building area of said lot, has been provided or referenced on said plans. With the construcoon of a basement, it is recommended that the {owest tioor e{evation be constructed at least twc (2) feet above any adjoining bodies of water unless a study Of facts reveals otherwise. Sbeuid any ground water be witnessed during the excavafio~ of said structure, the lowest floor elevation should be raised at least two (2) feet above the ground water [eve} and additional cons[ruction techniaues should be incorporated to alteviate future problems. LONGRIDGE ESTATES SECTION ONE PC 3 SLIDE 729 INSTR #200500063316 LOT # 11 13644 MONIQUE DRIVE WESTFIELD iN 46074 PLOT PLAN Prepared For: Pulte Homes of Indiana