HomeMy WebLinkAbout05110020-Site PlanNote:
Contractor should vedty sim
specific information depicted
hereon with the approved
construction plans for this
development.
Note:
Minimum Front yard - Vadabts
Minimum Between Residences- 6'
Minimum Rear Yard - 20'
Gar. FFE = 913.9
1st Fir FFE = 915.7
Bsmt FFE = 905,9
Drive Slope = 2.4%
BUCKINGHAM - ELEV 6C
FULL BSMT - 9' Wails
3 CAR - Side Entry
Wd Deck "1"
74 2'
HP
LOT Cf 11
+19,512 SF
PAD 913.6 PER PLAN
~ = Proposed Grade
~ = Drainage Flow
XX.X = Existing Grade
Flood Hazard Note:
Lot Number 11 lies within Zone "X" per the scaled location on
the Flood Insurance Rate Maps for Hamilton County. indiana
(Communit~ Panel #18057C0205F. dated February 19, 2003).
Note:
This drawing is base~ upon construction plans and/or record
drawings prepared by others and is not based upon a field survey.
COOR Consulting & Land Services. Corp. does not warrant the
correctness or th[egdty of this information. The contractor/owner
should verity existing conditions prior to construction. Any varying
field conditions or any discrepancy with the information contained
hereon should be immediately reported to COOR Consulting & Land
Services, Corp.; failure to do so would result in the contractor/owners
assumption of liability.
-303 WEST MAIN STREET KNIGHTSTOWN. INDIANA
(888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692
~2004-250.011 REV SONS: I
Note:
Conc Flatwork Sq. Ft = +1536
Public Walk Sq Ft = +420
Sod Sq Yds = -+336
Seeding Sq Ft = -+12586
The proposed construction grades depicted hereon are based upon
nformation, proposed grades and/or contours, taken from the
approved construction ptsns prepared for this subdivision. Untess
stated hereon, no information pertaining to but not limited to,
fluctuafing wa[er table elevations, soil types or conditions within the
building area of said lot, has been provided or referenced on said
plans. With the construcoon of a basement, it is recommended that
the {owest tioor e{evation be constructed at least twc (2) feet above
any adjoining bodies of water unless a study Of facts reveals
otherwise. Sbeuid any ground water be witnessed during the
excavafio~ of said structure, the lowest floor elevation should be
raised at least two (2) feet above the ground water [eve} and
additional cons[ruction techniaues should be incorporated to
alteviate future problems.
LONGRIDGE ESTATES
SECTION ONE
PC 3 SLIDE 729
INSTR #200500063316
LOT # 11
13644 MONIQUE DRIVE
WESTFIELD iN 46074
PLOT PLAN
Prepared For:
Pulte Homes of Indiana