Loading...
HomeMy WebLinkAbout05100158-Site PlanLot # 24-2, containing 10,400 S.F.±, in ~ ~ Cla~x~ume .~-o~g----- c.f~ ~,,~ IN 46074 Prepared Date: 10/18/05: By: proposed Bu)~"(,).' INVENTORY (5O'R/ AMA Community ResidcUone: S~de Yard = 51, Rear Yard = 20 Aggregate = 10' (8.H.) Zoning = S1 6round Cover Calculations: Drive = 797 SF'+ Public Walk =319 Private Walk =91 H)droseeding = 4,231 Sod =514 Sy+ , Rear of residence. Vb05.0042882 Lot # 242 Note ~ The gonoge tabbed flour elevation is 2.8 above the curb at the drive, per plan. E.H. of Indians finished Floor Elevation Information Pod Grade = 915,7 per plan Pod Grade + 0.7' = Garage FF£ (916.~.) ~rage ~ + 1.5' = Residential FFF (917.9) ResiSential FFE - 9.0' = Basement F~ (908.9) Note: S~nitary Sewer Top of Costing Information Upstream Mouhale. TC=914.95 Downstream Manhole, TC=914.5t per record drawing Assumed NonJh Scale: 1' = 30' %.. I Note: This drawing is based on construction plans or record drawings, end is not based upon o tield survey. ~he Schneider Corporation does not warrant the ocourocy or sufficiency of this informatien. Contractors should verify existing conditions prior to ~ny construction. Any discrepoucy found en this drawing should be reported to The Schneider Corporation immediotal~ failing to do so results in the contractors assumption of alt liability. Note: 'lhe basement elevetinn, depicted hereon, bas bees determined and based upon the pad grades and/on c.~tsurs taken from the construction plane for this esbdMsion. Unless stated, fie infon'notica abcut fluctuating water tobies, soil conditions, on esi types hos bees provided or stated on said Hens, It is recommended that the basement fmlsbad floor elevatinns be at least two feel above the normal po~ elevation of any ¢~ljoining bodies of water, unless a study of facts reveals ethemies. If during the exabvation process any ground ~ta' is ~tnesesd, The Schneider Cerparation should be notified,lmmediately. The besemest elevat~ should be raised two feet (2) above the ground water, and ~ddiflonal construction techniques should be incorporated to ellevinte future problems. Detail of ~'oued/ Storm Wate' flow pattern fa' indMdual lots, Note: Builder to ensure positive drainage away from DRAWNG TC=914.51 ?!dewelk to be planed 1, from property tine, 4 f~om back of curb, p~ plan. Note: Sump pump(sl to be placed by builda* es needed. J / distance of tee feet (10') between the 51.6' sanitary sewer and ~tar tine interels. L/ · ¢ ./ / --../. / OR~A~ EAS~mT ~'""~...~/ Note: Per C~rmel zoning onalnesce 26.1.1: residential disklct limits height to twesty-five feet {25'), however a dwelling ,,mey be iccressed in height to they-five feet (35) pro~ed the sl~e end rear ~res are inc~e~esa an additional one foot (1') for each one font (1') the structure exceeds the first twenty-five feet (25') in height. Flood Hazard Statement: The accuracy of any fined hazara aa[a ShOWn on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT lie within that s~ecia~ riced hazard zone AE as said land plots Dy scale on flood insurance rate map #180081 0205 F for the City of Carmel indiana dated February 19. 2003. FLOOD HAZARD STATEMENT CERllFiCAllON ¢. '". STATE OF