Loading...
HomeMy WebLinkAbout05100165-Site Plan~.~. t 200400080247 County, 3791 Dolon Way (70'R~ Ca.el, IN ~607~ Pr~ared Date:'* 10/18/05 '. B~ AMA ~ ~8~ Manuel ~ Marie Garcia ~mual~ R~fi~ ~ Y~d = 5' T~Ol~95 Re~ Y~d = 20' Agitate = 10' (B.H.) Z~Ag = S1 Ground Cover Calculations: Drive ; 1.181 Public Walk =451 SF'+ Private Walk = 205 Hydrosesding =5.692 SF+ Sod =555 Sy+ , from Rear of residence Note: 'the garege finished flo~ ~evatlas is 2.1 ubove th curb nt the dri~ ,$!dew~k to be ploond '~ f from property line, 11' from back of curb, per plan. Note: Sump pump(s) to be A-- placed by builder ns needed. D A,. o nra H~dr,~t ...... R~a Line of ~e mla, e U~e (~. / asq ....... E~'nmt Line PE~ REC~D Note: 1his drawing is based on construction plans or record drawings. and is not based upon a field survey. ]he Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to 'l~e Schneider Corporation immadiatei~ foiling to do so results in the contrectors assumption of ell liability· Note: The basement elevate, depicted hereon, has bees determined esd bused upon the p~d 9redes end/or cestoure taken from the construction plans for thb subdivision. Unless stated no Information about fluctuating ~oter tables, ~ condiU~e, or sell t~pes has been pro~ded or stated on md pass It e recommond~ that the hese~nt finished floor elevations be at leest two font (2) above the normal pool elevation of any adjoining bed~ of wnter, unless a study of focte reveo~s othere,~e. If during the ~xcavation process any Found water is witneese~ 1he Schneider Cerporaties should be notified immediste~y. 1he basemest elevation should be raised two feet 12') above the ~sund ~ter, and additiasa~ construction techniques ~suld be Incorporated to ~eviate future problems. Detail of Ceaasd/Storm ~ Water flow pattern for , ndNidual Iot~. \ Note: Builder to essure positive drainage oway from structure(e). Vb05.0042886 - Lot # 190 Assumed North Scale: 1" = Note: Sanitary Sewer Top of ~sting Information Upstream Monheie, TC= 916.60 Downstream aanhole, TC=915.95 per record drawing distance of ten feet (10') between the sanitary sewer and water line laterals. FLOOD HAZARD STATEMENT CERTIFICATION i S0303 } \ ~sw~ SEC~ Note: P~ C~ z~iag ~d~asce 26.t.1: msld~fi~ die,ct t~lts he~t to t~t~fl~ feet (25'). ~o~e~ a d~alhg may be ~d · irt~fl~ f~t (35') Fo~d~ the ~ are h~d ~ addit[~ ~e f~t ~t (1') the structure exc~ds the r~st tw~t~fi~ feet (25') ~ be~t. L 82.93' Pm .u. -- o o o R.H. of Indiana J Finished Floor Devotion Information Pad Grade = 916.9 per plan Pad Grade + 0.7' = Garage FEI: (917.6) Garage FIE + 1.5 = ,Residential FIE (919.1) Residential FIE - 9.0 = Basement FIE (910.1 Flood Hazard Statement: The accuracy of an) flood hazard data shown on this report Is subject [o map scale uncertainty and to any other uncertainty in [(3cation or elevation on the referenced flood insorance rate map ALL of the within described fend DOES NOT lie within that special flood hazard zone AE as said [and plots by scale on flood insurance rate map #180081 0205 F for the City of Carmel. Indiana dated FebruaB. 19. 2003.