1200A METER CENTER
<9:
NEMA 3R
PANEL
LA
PANEL
HP
(4
-
5
0
0
k
c
m
i
l
,
1
#
1
/
0
G
)
3
1
/
2
"
C
(
3
8
0
A
)
(I
N
C
R
E
A
S
E
D
G
R
O
U
N
D
S
I
Z
E
P
E
R
T
E
N
A
N
T
)
(4
#
2
,
1
#
8
G
)
1
1
/
4
"
C
(
9
5
A
)
3
1
/
2
"
C
FAULT CURRENT CALCULATIONS (END OF CONDUCTOR)
LOCATION DESCRIPTION STARTING ISC
MINIMUM
CONDUCTOR
LENGTH
PHASE
MULTIPLIER VOLTAGE
# OF
CONDUCTOR
SETS
C VALUE ISC END
@ METER CENTER 52,000 50 1.73 208 4 22,737 42,011
@ PANEL HP 42,011 5 1.73 208 1 6,044 32,590
@ PANEL LA 42,011 85 1.73 208 1 26,706 19,890
@ PANEL LC 42,011 20 1.73 208 1 26,706 33,298
LOAD CALCULATION
LOCATION AREA
LIGHTING
(3.5VA/SQFT *
1.25)
RECEPTACLES
(1VA/SQFT)
MECHANICAL
(PER MECH OR
8VA/SQFT)
SHOW WINDOW
(200VA/FT)
SPARE
(5VA/SQFT)TOTAL
UNIT A 2240FT^2 9.8kVA 2.2kVA 17.9kVA 4.0kVA 11.2kVA 45.16kVA
UNIT B 3200FT^2 14.0kVA 3.2kVA 25.6kVA 4.0kVA 16.0kVA 62.80kVA
UNIT C 2400FT^2 10.5kVA 2.4kVA 19.2kVA 4.0kVA 12.0kVA 48.10kVA
HOUSE PANEL 9.5kVA
TOTAL LOAD 165.6kVA
TOTAL AMPERAGE 460A
VOLTAGE 208 PHASE 3
UTILITY COMPANY PAD
MOUNTED TRANSFORMER
<9:6(&21'$5<
1 ONE-LINE DIAGRAM
NOT TO SCALE
NOTES:
1.NEW WIRING SHALL BE THHN/THWN-2 INSULATED COPPER
UNLESS OTHERWISE NOTED.
40
0
A
3
P
40
0
J
J
N
PANEL
LC
(4
-
5
0
0
k
c
m
i
l
,
1
#
1
/
0
G
)
3
1
/
2
"
C
(
3
8
0
A
)
(I
N
C
R
E
A
S
E
D
G
R
O
U
N
D
S
I
Z
E
P
E
R
T
E
N
A
N
T
)
4[(4-350kcmil)3"C] (1200A)
2
2
2
2
DIGITAL ASTRONOMICAL
TIME SWITCH WITH BATTERY
BACKUP (TORK OR EQUAL)
PC
PHOTOCELL LOCATED ON ROOF
AND FACE TOWARDS NORTH
C
AUTO
OFF
ON
HP-3
HP-1
120V
3-POSITION
SELECTOR SWITCH
L N
30A LIGHTING
CONTACTOR
2 EXTERIOR BUILDING LIGHTING CONTROL DETAIL
NOT TO SCALE
EXTERIOR LIGHTING
EXTERIOR LIGHTING
NOTE: PROVIDE BOTH SWITCHED AND
UNSWITCHED CIRCUIT TO EM LIGHTING
DIGITAL ASTRONOMICAL
TIME SWITCH WITH BATTERY
BACKUP (TORK OR EQUAL)
PC
PHOTOCELL LOCATED ON ROOF
AND FACE TOWARDS NORTH
C
AUTO
OFF
ON
HP-8
HP-6
120V
3-POSITION
SELECTOR SWITCH
L N
30A LIGHTING
CONTACTOR
3 EXTERIOR POLE LIGHTING CONTROL DETAIL
NOT TO SCALE
EXTERIOR LIGHTING
EXTERIOR LIGHTING
130168
RE
V
I
S
I
O
N
S
CE
R
T
I
F
I
C
A
T
I
O
N
DR
A
W
N
B
Y
:
B
E
K
CH
E
C
K
E
D
B
Y
:
B
E
K
CL
I
E
N
T
S
I
G
N
O
F
F
:
IS
S
U
E
D
A
T
E
:
1
1
/
4
/
1
3
TH
I
S
D
R
A
W
I
N
G
A
N
D
T
H
E
I
D
E
A
S
,
D
E
S
I
G
N
S
A
N
D
CO
N
C
E
P
T
S
C
O
N
T
A
I
N
E
D
H
E
R
E
I
N
A
R
E
T
H
E
E
X
C
L
U
S
I
V
E
IN
T
E
L
L
E
C
T
U
A
L
P
R
O
P
E
R
T
Y
O
F
C
U
R
R
A
N
A
R
C
H
I
T
E
C
T
U
R
E
,
AN
D
A
R
E
N
O
T
T
O
B
E
U
S
E
D
O
R
R
E
P
R
O
D
U
C
E
D
,
WH
O
L
E
O
R
I
N
P
A
R
T
,
W
I
T
H
O
U
T
T
H
E
W
R
I
T
T
E
N
CO
N
S
E
N
T
O
F
C
U
R
R
A
N
A
R
C
H
I
T
E
C
T
U
R
E
.
C
O
P
Y
R
I
G
H
T
2
0
1
2
,
C
U
R
R
A
N
A
R
C
H
I
T
E
C
T
U
R
E
31
7
.
2
8
8
.
0
7
5
3
F
A
X
31
7
.
2
8
8
.
0
6
8
1
V
O
I
C
E
IN
D
I
A
N
A
P
O
L
I
S
,
I
N
4
6
2
5
0
69
2
5
E
A
S
T
9
6
T
H
S
T
.
,
S
U
I
T
E
1
0
5
C
U
R
R
A
N
WW
W
.
C
U
R
R
A
N
-
A
R
C
H
I
T
E
C
T
U
R
E
.
C
O
M
E0.2
AD
D
E
N
D
U
M
#
1
1
1
/
2
7
/
1
3
A A