HomeMy WebLinkAboutS401 121103.pdfG1.BUILDING CODES: Model:International Building Code 2006 Local:Indiana Building Code 2008 Steel:American Institute of Steel Construction 360, ASD Thirteenth Edition Concrete:American Concrete Institute, 318-05. G2.DESIGN LOADS: Roof Dead Load:20 psf Live Load:25 psf SNOW Flat Roof Snow Load:20 psf Snow Exposure Category:C Snow Exposure Factor:1.0 Snow Importance Factor:1.0 Thermal Factor:1.0 WIND Basic Wind Speed:90 mph Wind Importance Factor:1.0 Building Classification:II Wind Exposure Category:C SEISMIC Importance Factor:1.0 Seismic Design Category:II Spectral Response, Sds:0.156 Spectral Response, Sd1:0.130 Site Class:D Basic Resisting System:H.1: Structural System Not Specifically Detailed for Seismic Resistance Response Modification, R 3.0 Design Base Shear:5.19%W Analysis Procedure:Equivalent Lateral Force Procedure G3.Reactions and forces indicated are unfactored, Allowable Strength Design loads. G4.If Drawings and specifications are in conflict, the most stringent restrictions and requirements shall govern. Contractor shall bring all discrepancies to the attention of the engineer immediately. G5.Verify all existing conditions prior to any construction or fabrication. If different than shown, notify engineer/architect immediately for modification of drawings. G6.All contractors are required to coordinate their work with all disciplines to avoid conflicts. The architectural, mechanical, electrical and plumbing aspects are not in the scope of these drawings. Therefore, all required materials and work may not be indicated. It is the contractor's responsibility to coordinate these drawings with all other construction documents. Refer to architectural drawings for all dimensions not shown on these drawings. locations,their work with all other disciplines. G7.The contract documents represent the structure only. They do not indicate the method of construction. The contractor shall provide all measures necessary to protect the structure during construction. Such measures shall include, but not limited to, bracing, shoring, underpinning, etc. McComas Engineering is not responsible for the contractor's means, methods, techniques, sequences or safety procedures during construction. G8.Notes and details shall take precedence over general structural notes. Where no details or sections are shown, construction shall conform to similar work on the project. Typical sections and details may not be cut on the plans, but apply unless noted otherwise. G9.Provisions for future expansion: Vertical:None Horizontal:None GENERAL NOTES SF1.Design Soil Bearing Pressure: Spread Footings 1500 psf Wall Footings 1500 psf (Assumed values to be varified prior to construction) SF2.Soil to be stripped, compacted and tested in accordance with the recommendations of the soils engineer and project specifications. SF3.Footings shall be placed on firm, undisturbed soil or on engineered fill. Engineered Fill: Naturally or artificially graded mixture of natural or crushed gravel, crushed stone, and natural or crushed sand; ASTM D 2940; with at least 90 percent passing a 1-1/2-inch sieve and not more than 12 percent passing a No. 200 sieve. SF4.Slabs shall be placed on compacted, free-draining, frost-free drainage course. Drainage Course: Narrowly graded mixture of washed crushed stone, or crushed or uncrushed gravel; ASTM D 448; coarse-aggregate grading Size 57; with 100 percent passing a 1-1/2-inch sieve and 0 to 5 percent passing a No. 8 sieve. All fill shall be compacted to a minimum dry density of 95% of the modified Proctor maximum dry density (ASTM-D1557), placed in 6" to 8" lifts. Pea gravel may not be used as fill. Utility trenches and excavations under the foundations or slabs shall meet the same requirements. See soils investigation report for further recommendations. SF5.Undercutting of the soil for foundation and/or slab placement may be required. These drawings do not indicate the entire scope of undercutting, fill or bad soil removal that may be required to attain the design soil bearing pressures. It is the responsibility of the contractor to obtain a soils investigation report, before bidding, to assess the extent of excavation and compaction that may be required to meet the design criteria. The contractor shall retain the services of a soils engineer to monitor all backfilling operations and to inspect footing bearing material. A report certified by the soils engineer shall be furnished to the architect/engineer verifying that all foundations were placed on a material capable of sustaining the design bearing pressures. SF6.If dewatering is required, sumps shall not be placed within the foundation excavation. SF7.Maintain a maximum slope between adjacent footing bearing elevations of 2 horizontal to 1 vertical. Maintain a 2 horizontal to 1 vertical slope next to existing foundations to avoid undermining foundations. SF8.No horizontal joints are permitted in any foundation. Vertical joints are permitted only in wall footings. SF9.Shallow foundations may be earth-formed where the excavation permits. If earth-forming is used, add 2" to the width and length of all foundations. SF10.The bottom of all foundations shall be a minimum of 36" below final grade. SHALLOW FOUNDATION AND SLAB ON GRADE NOTES RC1.All concrete shall have the following 28 day compressive strengths: LOCATION STRENGTH AIR ENTRAINMENT Wall Footings, Spread Footings:3000 psi 2% All concrete exposed to freeze/thaw, exterior slabs, piers, walls, columns, grade beams, concrete exposed to freeze/thaw: 4000 psi 6% Interior slabs on grade, fill for metal deck:4000 psi Non AE RC2.All reinforcing steel shall be detailed, supplied and placed in accordance with ACI 315, ACI 318 and CRSI MSP-1. RC3.All reinforcing steel shall be shop fabricated and, where applicable, shall be wired together and conform to ASTM A-615, Grade 60. RC4.Chamfer edges of exposed concrete 3/4", unless noted otherwise. RC5.Contractor shall make four, 6"x12" test cylinders for each 50 cubic yards of concrete poured for each days operation. Break 1 at 7 days, 2 at 28 days and retain spare. RC6.All welded wire fabric shall conform to ASTM A185, Fy(min) of 65 ksi. All welded wire fabric laps shall be 8". RC7.All finished concrete, concrete formwork and falsework shall be in accordance with ACI 301. Contractor is solely responsible for the design and construction of all formwork, falsework and shoring. RC8.Provide the following coverages over reinforcing: LOCATION Footings:Bottom and Unformed edges 3" Footings:Formed edges and top 2" Slab on grade:Welded wire fabric Upper Third Fill for Metal Deck:Welded wire fabric Upper Third Reinforcing Steel:Bottom 2" RC9.Provide sleeves for all openings in grade beams or walls to totally separate pipe from concrete. REINFORCED CONCRETE NOTES (Foundations, Slabs & Walls) M1.Minimum 28 day compressive strength of concrete masonry units shall be 2800 p.s.i. based on net area of the unit. Specified design compressive strength of masonry shall be f'm = 2000 p.s.i. All units for exterior walls, load-bearing walls and shear walls shall be normal weight block. M2.All mortar shall be Type S. No admixtures may used unless approved by architect/engineer. Mortar shall not be used for grouting cores or filling bond beams. M3.All block shall be laid in a running bond pattern. M4.Course grout shall be used were grouting is required. Slump shall be 8" +/- 1". Minimum grout compressive strength shall be 3000 p.s.i. M5.All reinforcing shall be ASTM A615 Grade 60 (Fy=60 ksi). Lap all reinforcing a minimum of 48 bar diameters. M6.See architectural and specifications for all control joint locations. Reinforcing in bond beams shall be discontinuous at control joints. M7.Provide ladder type horizontal joint reinforcement at 16" o.c. Side rods and cross rods shall be #9 wire, galvanized, see specifications. Cut joint reinforcement at control joints. M8.Provide "L" bars at all bond beam corners as required. M9.Fill cores of block solid with grout two full courses below the bearing of all beams or lintels supported on masonry. M10.All attachments to block shall be made with Hilti HX 1/2" diameter x 3" sleeve anchors, unless noted otherwise. Anchors shall be installed per manufacturer's recommendations. M11.See typical schedules for masonry and steel lintels not indicated on plans. M12.All masonry units below grade to be grouted solid. M13.Provide ties to all structural steel. M14.All interior, non-load bearing masonry walls over 12'-0" high, shall be supported on thickened slab as per typical detail. Wall vertical reinforcing shall be #5 @ 48" OC full height. Unless noted otherwise. M15.All cores with reinforcing steel shall be grouted solid, full height of wall. MASONRY AND REINFORCED MASONRY NOTES SS1.All structural steel shall conform to the following: W Shapes ASTM A992, Grade 50. Angles, Channels, Plates, Bars ASTM A36 (Fy=36 ksi) HSS Tubes ASTM A500, Grade B (Fy=46 ksi) HSS Pipes ASTM A500, Grade B (Fy=42 ksi) Anchor Rods ASTM F1554, Grade 36 SS2.All steel shall be detailed, fabricated and erected in accordance with: AISC 360-05 "Specification for Structural Steel Buildings", Allowable Strength Design (ASD) AISC 303-05 "Code of Standard Practice" SS3.If beam reaction is not indicated, design connection for minimum 10 k reaction. SS4 All bolted connections shall be made with 3/4" diameter, A325 bolts with nuts and washers, unless otherwise noted. All connections shall be shear bearing connections tightened to snug-tight condition, unless otherwise noted. SS5.All shop and field welds shall be made using E70 electrodes or equivalent. SS6.All headed concrete anchors shall be ASTM A108 (Fy=50 ksi), 3/4" diameter x 4" after welding, unless noted otherwise. SS7.Steel fabricator shall obtain the size and location of all openings for grilles, louvers, etc. before proceeding with the fabrication and erection of any required frames. SS8.Provide Heckman #129 and #130 channel slot and channel slot anchors at all columns that abut masonry walls, unless noted. SS9.Provide temporary bracing of the structure until all permanent lateral support is in place. SS10. Structure Stability: The entire roof and/or floor decking materials must be fully erected and connected to the supporting steel before temporary, erection bracing is removed. SS11.RD = Roof Drain location. Provide steel frame for drains. See other drawings for actual drain type, number, size, etc. Coordinate with drain contractor. STRUCTURAL STEEL NOTES SJ1.Provide all joists, bridging and accessories for the complete erection of joists in accordance with the current Steel Joist Institute "STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB STEEL JOISTS AND JOIST GIRDERS" and Underwriters Laboratories "STANDARD, FIRE TESTS OF BUILDING CONSTRUCTION AND MATERIALS". SJ2.Bridging shall be completely erected and joists aligned before any construction loads are placed on joists. SJ3.Do not weld bottom chord of joists to columns unless noted on drawings. SJ4.Install erection bolts at all joist girder to column and joist to column connections. SJ5.Where ballasted roofing is not shown on architectural drawings, provide uplift bridging at all joists as per "STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB STEEL JOISTS AND JOIST GIRDERS" for a net uplift load of 12 psf. STEEL JOIST NOTES MD1.All metal deck material, fabrication and installation shall conform to Steel Deck Institute" SDI SPECIFICATIONS MD2.Roof deck shall be welded using a 36/4 pattern with (1) #10 TEK sidelap fastener unless otherwise shown in typical detail. MD3.Provide TS 2 1/2x 2 1/2x 1/8 deck support, field welded to joist or beam at all deck span changes. MD4.Provide L3x3x1/4 deck support at all columns where required, unless noted. MD5.Provide 20 gauge cover plate at all roof deck span changes. MD6.Provide L3x3x1/4 at all unsupported edges of deck and around roof perimeter, unless otherwise noted. MD7.All deck shall be provided in a minimum of 3-span lengths where possible. STEEL DECK NOTES SF1.All light gage, cold formed steel (CFS) members shall conform to the following (See drawings for application): TYPE SIZE OLD GAGE SPACING GRADE Exterior Wall Studs 600 S 162-54 16 16" oc, u.n.o.ST33H (33 ksi) Interior Load-Bearing Studs 600 S 162-54 16 16" oc, u.n.o.ST33H (33 ksi) SF2.All sheet steel shall comply with ASTM A1003. Coating shall be G90 galvanizing. SF3.Provide steel tracks complying with ASTM C955, thickness to match studs, 2" flange width. SF3.Provide 1/2" ASTM F1554, Grade 36 hooked anchor bolts at all steel tracks, u.n.o. Anchor bolt spacing = 48" OC, u.n.o. Provide anchor bolt at 8" from the ends of all walls, u.n.o. SF6.All cold formed steel members shall comply with the requirements of the latest AISI Specification. SF7.Field welding is not permitted. Provide screwed connections. SF8.For all non-load bearing studs, provide deflection clips isolating the stud from the primary structure. SF9.Provide 5/8" plywood sheathing on outside face of all exterior wall studs. COLD FORMED STEEL FRAMING NOTES CFS HEADER SCHEDULE OPENING HEADER JAMB (INTERIOR NON-LOAD BEARING WALLS) 0'-0" TO 8'-0" 8'-1" TO 10'-0" 10'-1" TO 12'-0" 12'-1" TO 16'-0" (2) 600S162-33+ (2) STUD DEPTH T150-33 (2) 800S162-33+ (2) STUD DEPTH S162-33 (2) 1000S162-54+ (2) STUD DEPTH S162-54 (2) 1200S162-54+ (2) STUD DEPTH S162-33 MIN (2) 362S162-33 (16'-0" MAX HGT) MIN (2) 600S162-33 (20'-0" MAX HGT) MIN (2) 362S162-33 (14'-0" MAX HGT) MIN (2) 600S162-33 (20'-0" MAX HGT) MIN (2) 362S162-33 (14'-0" MAX HGT) MIN (2) 800S162-33 (20'-0" MAX HGT) MIN (2) 600S162-33 (14'-0" MAX HGT) MIN (2) 800S162-54 (20'-0" MAX HGT) CFS HEADER SCHEDULE (EXTERIOR NON-LOAD BEARING WALLS) OPENING HEADER JAMB (6) 0'-0" TO 6'-0" 6'-1" TO 8'-0" 8'-1" TO 12'-0" (2) 600S162-54+ (2) STUD DEPTH T150-54 (2) 800S162-54+ (2) STUD DEPTH S150-54 (2) 1200S162-68+ (2) STUD DEPTH S150-68 MIN (2) 600S162-54 MIN (2) 600S162-68 MIN (2) 600S250-68 CFS HEADER SCHEDULE NOTES: 1. WEB STIFFENERS REQUIRED AT EACH END OF HEADERS AND SILL. 2. HEADERS ARE BOXED SECTIONS, SEE DETAILS. 3. JAMBS ARE BACK TO BACK SECTIONS, SEE DETAILS. 4. PROVIDE SAME FRAMING FOR OPENING SILL AS SHOWN FOR HEADER. 5. SCHEDULE APPLIES TO 16'-0" MAXIMUM STUD UNBRACED LENGTH (WALL HEIGHT). 6. MINIMUM JAMB DEPTH SHOWN, ACTUAL JAMB DEPTH TO MATCH STUD DEPTH IF LARGER. 1717 East 116th Street, Suite 200 Carmel, Indiana 46032 Structural Engineers 317-580-0402 www.mccomaseng.com McCOMAS ENGINEERING SS R O C P R O F E. A I GN N IO LA E RE R SA STATE OF 860325 N NI DNo. A ENI RM IE D EGN T S EY MOCDEc DR A W N B Y CH E C K E D B Y CL I E N T S I G N O F F IS S U E D A T E RE V I S I O N S CE R T I F I C A T I O N 13270MEI SD S CR M OC T O B E R 2 5 , 2 0 1 3 AD D E N D U M # 1 11 . 2 7 . 2 0 1 3 1 AD D E N D U M # 2 2 12 . 1 1 . 2 0 1 3 S401S401S401S401 O/O OUT TO OUT OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OH OVER HEAD OPNG OPENING OPP OPPOSITE OPP HD OPPOSITE HAND OSB ORIENTED STRAND BOARD OSL OUTSTANDING LEG OVS OVERSIZE HOLE PAF POWDER ACTUATED FASTENER PC PRECAST PL PLATE PLF POUNDS PER LINEAR FOOT PLYWD PLYWOOD PNL PANEL PROJ PROJECTION PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSL PARALLEL STRAND LUMBER PT PRESSURE TREATED PTN PARTITION R RADIUS RD ROOF DRAIN REF REFERENCE REINF REINFORCE(D) (ING) (MENT) REQ'D REQUIRED REV REVISION/REVISED RO ROUGH OPENING RRD ROOF RELIEF DRAIN RTN RETURN RTU ROOF TOP UNIT RW RETAINING WALL SCHED SCHEDULE SECT SECTION SHT SHEET SIM SIMILAR SJ SAWCUT JOINT SJI STEEL JOIST INSTITUTE SL SLOPED SPA SPACE(S) SPECS SPECIFICATIONS SQ SQUARE SS STAINLESS STEEL SSL SHORT SLOTTED HOLES STD STANDARD STIFF STIFFENERS STL STEEL STRUCT STRUCTURAL SYMM SYMMETRICAL T&B TOP AND BOTTOM T&G TONGUE AND GROOVE TB TIE BEAM TC TOP CHORD TCX TOP CHORD EXTENSION TEMP TEMPERATURE TF TRENCH FOOTING THK THICK THKS THICKENED SLAB THR'D THREADED TL TOTAL LOAD TOP'G TOPPING TRANS TRANSVERSE TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD w/WITH WD WOOD WO WINDOW OPENING (MASONRY) WP WORKING POINT WT WEIGHT WWF WELDED WIRE FABRIC ELEVATION TOP AND BOTTOM OF LIST T/"ELEVATION, TOP OF" B/"ELEVATION, BOTTOM OF" T/BB TOP OF BOND BEAM T/BM TOP OF BEAM T/CONC TOP OF CONCRETE T/F TOP OF FOOTING T/LDG TOP OF LEDGE T/MAS TOP OF MASONRY T/P TOP OF PIER T/SLAB TOP OF SLAB T/STL TOP OF STEEL T/W TOP OF WALL T/GB TOP OF GRADE BEAM T/CAIS TOP OF CAISSON B/PL BOTTOM OF PLATE B/F BOTTOM OF FOOTING SPECIAL CHARACTERS °DEGREE ±PLUS OR MINUS ELEVATION Ø DIAMETER AR ANCHOR RODS ABV ABOVE ACI AMERICAN CONCRETE INSTITUTE ADD'L ADDITIONAL ADH ADHESIVE ADJ ADJACENT AESS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL AFF ABOVE FINISHED FLOOR AGGR AGGREGATE AHU AIR HANDLING UNIT AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE ALUM ALUMINUM ALT ALTERNATE APPROX APPROXIMATE ARCH ARCHITECT ARCH'L ARCHITECTURAL ASTM AMERICAN SOCIETY OF TESTING MATERIALS AWS AMERICAN WELDING SOCIETY L ANGLE BAL BALANCE BB BOND BEAM B/B BACK TO BACK BC BOTTOM CHORD BD BOARD BLDG BUILDING BLK BLOCK BLW BELOW BM BEAM BOTT BOTTOM BP BEARING PLATE BRDG BRIDGING BRG BEARING BRK BRICK BS BOTH SIDES BSMT BASEMENT BTWN BETWEEN BUC BUILT UP COLUMN c CAMBER C/C CENTER TO CENTER CANT CANTILEVER CAIS CAISSON CFS COLD FORMED STEEL CJ CONTROL AND/OR CONSTRUCTION JOINT CL CENTERLINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN COORD COORDINATE COMP COMPACTED CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CTR CENTER CTR'D CENTERED DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DL DEAD LOAD DLT DEEP LEG TRACK DO DITTO DN DOWN DTL DETAIL DWG DRAWING DWL DOWEL EA EACH EE EACH END EF EACH FACE EJ EXPANSION JOINT ENG ENGINEER ELEV ELEVATION ELECT ELECTRICAL EOD EDGE OF DECK EOS EDGE OF SLAB EQ EQUAL EQUIV EQUIVALENT ES EACH SIDE EW EACH WAY EXIST EXISTING EXP EXPANSION EXT EXTERIOR F/FACE OF FD FLOOR DRAIN FDN FOUNDATION FIN FINISH FLR FLOOR FLG FLANGE FS FARSIDE FTG FOOTING GA GAUGE GALV GALVANIZED GB GRADE BEAM GC GENERAL CONTRACTOR GL GLULAM GR GRADE HC HOLLOW CORE HD HOLD DOWN HGT HEIGHT HI HIGH HK HOOK HORIZ HORIZONTAL HP HIGH POINT HS HEADED STUD HSS HOLLOW STRUCTURAL SECTION ID INSIDE DIAMETER IF INSIDE FACE INFO INFORMATION INT INTERIOR INV INVERT JST JOIST JT JOINT K KIP KO KNOCK OUT LB POUND LDG LEDGE LG LONG LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LNTL LINTEL LSL LONG SLOTTED HOLES LONG LONGITUDINAL LP LOW POINT LVL LAMINATED VENEER LUMBER MAS MASONRY MAT'L MATERIAL MAX MAXIMUM MBM METAL BUILDING MFR MCJ MASONRY CONTROL JT MECH MECHANICAL MEZZ MEZZANINE MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MOM MOMENT MSW MASONRY SHEAR WALL MSL MEAN SEA LEVEL MTL METAL NO NUMBER NS NEAR SIDE NTS NOT TO SCALE ABBREVIATIONS LIST WALL FOOTING SCHEDULE (v2 simple) Mark DimensionsBottom Reinf RemarksWidthThickness Longitudinal ReinfTransverse Reinf NoSizeSizeSpa WF181' - 6"1' - 0"2#5NA0" WF242' - 0"2' - 8"3#5NA0" WF302' - 6"2' - 8"4#5NA0" WF363' - 0"2' - 8"5#5NA0" Wall Footing Schedule Notes: 1. See plan for actual footings used. 2. Reinforcing clearance at bottom and sides of footings = 3" 3. Use concrete brick of CRSI Class 3, CHCP wire bar supports @ 36". COLUMN FOOTING SCHEDULE (v2 simple) Mark Ftg DimensionsBottom Reinforcing RemarksWidthLengthThickness Short DirectionLong Direction NoSizeLengthNoSizeLength F15' - 0"5' - 0"2' - 8"6#54' - 6"6#54' - 6" F26' - 0"6' - 0"1' - 0"7#55' - 6"7#55' - 6" F36' - 0"6' - 0"2' - 8"7#55' - 6"7#55' - 6" Column Footing Schedule (Special) Notes: 1. Reinforcing clearance at bottom and sides of footings = 3" 2. Use concrete brick of CRSI Class 3, CHCP wire bar supports @ 36". PIER SCHEDULE (v2) Mark Pier SizeVert ReinfTies RemarksWidthLengthNoSizeSizeSpa P11' - 4"1' - 4"4#6#31' - 0" Pier Schedule Notes: 1. Provide P1 reinforcing at each steel column, UNO. 2. Provide 1 1/2" concrete cover over ties. 3. See typical pier elevation for tie and vertical bar placement. 4. Provide CRSI Typ Bar Bend No T5 ties for all vertical face bars, if there are more than for vertical bars in pier. MASONRY WALL SCHEDULE (v2) MarkTypeHoriz Reinf Vert ReinfDowel Reinf LocationRemarksSizeSpaSizeSpa MW66" CMUN/A#54' - 0"#54' - 0"CenterGROUT SOLID MW88" CMUN/A#54' - 0"#54' - 0"CenterGROUT SOLID Masonry Wall Schedule Notes: 1. Provide 2" concrete cover from outside face for bars in each face. 2. Grout all cores with rebar solid, unless solid grouted wall is shown. COLUMN SCHEDULE (v2 marked) MarkSize Base Plate SizeAnchor Rods RemarksThickness WidthLengthSize (Dia)Quantity C1HSS6X6X3/83/4"1' - 2"1' - 2"3/4"4 C2HSS8X8X3/83/4"1' - 4"1' - 4"3/4"4 Column Schedule Notes: 1. See typical details for column base construction. BRICK LINTEL SCHEDULE FOR ALL LINTELS NOT INDICATED ON PLANS Clear Opening Steel Angle Up to 5'-0"L3 1/2 x 3 1/2 x 5/16 5'-1" up to 7'-0"L5 x 3 1/2 x 5/16 7'-0" up to 10'-0"L6 x 3 1/2 x 3/8 Brick Lintel Schedule Notes: 1. All lintels shall have 8" bearing on each end of opening. 2. All exterior lintels shall be galvanized. 3. All interior lintels shall be shop primed with two coats of epoxy paint. 10'-1" up to 12'-0"L6 x 6 x 3/8 SLAB ON GRADE SCHEDULE (v2) MarkThicknessReinforcing Control Jt Depth Reinf Clearance Control Jt Spa Vapor Retarder Sub-Base Depth Remarks SOG04P4"6x6-W1.4xW1.4 WWF1"1 1/2"13' - 0"Plastic6"SEE NOTE #1 Slab On Grade Notes: 1. Fill below slab placed by contractor. Concrete slab to be placed by tenant. 1 2