Loading...
HomeMy WebLinkAboutS405 121103.pdfA VENEER - SEE ARCH GRADE OR PAVEMENT 4" SOLID CMU CFS WALL ANCHOR ROD CONC SLAB BY TENANT 1/2" EXP JT MAT'L 8" KO BOND BM w/ (2) #5 CONT WALL FTG (WF) REINFORCING CENTERLINE OF FTG 2" RIGID INSULATION SEE ARCH #5 DOWEL @ 4'-0" OC 5" SHEATHING 7 5/8" 2 3/4" 3 5/8" A VENEER - SEE ARCH GRADE OR PAVEMENT 4" SOLID CMU CFS WALL ANCHOR ROD CONC SLAB BY TENANT 1/2" EXP JT MAT'L 8" KO BOND BM w/ (2) #5 CONT WALL FTG (WF) REINFORCING CENTERLINE OF FTG 2" RIGID INSULATION SEE ARCH #5 DOWEL @ 4'-0" OC ALING FACE OF CFS FRAMING w/ CMU BELOW ADDITION 2x FRAMING AND SHEATHING AT WALL BUMP OUT (TYP) (2) ANCHOR RODS AT WALL BUMP OUT SILL PLATE (TYP) (2) #5 DOWEL @ BUMP OUT 6" KO BOND BM w/ (1) #5 CONT 5"1' - 4" 4" SOLID CMU SITE PAVEMENT SEE CIVIL 1/2" EXP JT MAT'L WALL FTG (WF) REINFORCING CENTERLINE OF FTG 2" RIGID INSULATION SEE ARCH CONC SLAB BY TENANT x#5 @ 4'-0" OC1'-6" 1'- 6 " 1/2" EXP JT MAT'L STOREFRONT SEE ARCH EQUAL EQUAL A T/STL +19' - 1 1/2" PLAN SEE T/PARAPET +(SEE ARCH) BEAM JOIST DECK S403 8 L3x3x1/4xCONT CFS FRAMING - SEE ARCH SHEATHING SHEATHING EXT FINISH - SEE ARCH SEE ARCH SHEATHING SEE ARCH DRAWINGS FOR ADDITIONAL PARAPET INFO CFS CLIP 2 SEE ARCH DRAWINGS FOR ADDITIONAL PARAPET INFO SEE ARCH PLAN SEE T/STL +(SEE PLAN) BEAM JOIST DECK SHEATHING S403 8L4x4x1/4xCONT EXT FINISH - SEE ARCH SHEATHING SHEATHING T/PARAPET +(SEE ARCH) CFS FRAMING - SEE ARCH 2 SEE ARCH DRAWINGS FOR ADDITIONAL PARAPET INFO SEE ARCH PLAN SEE T/STL +(SEE PLAN) BEAM JOIST DECK SHEATHING L4x4x1/4xCONT EXT FINISH - SEE ARCH SHEATHING SHEATHING S403 8 T/PARAPET +(SEE ARCH) CFS FRAMING - SEE ARCH CFS CLIP 1 T/STL +14' - 2 1/2" BEAM STOREFRONT - SEE ARCH AWNING - SEE ARCH D T/PARAPET +(SEE ARCH) BEAM JOIST DECK L3x3x1/4xCONT CFS FRAMING - SEE ARCH SHEATHING SHEATHING EXT FINISH - SEE ARCH SHEATHING SEE ARCH DRAWINGS FOR ADDITIONAL PARAPET INFO CFS CLIP S403 8 SEE ARCH PLAN SEE T/STL +20' - 6" 1717 East 116th Street, Suite 200 Carmel, Indiana 46032 Structural Engineers 317-580-0402 www.mccomaseng.com McCOMAS ENGINEERING SS R O C P R O F E. A I GN N IO LA E RE R SA STATE OF 860325 N NI DNo. A ENI RM IE D EGN T S EY MOCDEc DR A W N B Y CH E C K E D B Y CL I E N T S I G N O F F IS S U E D A T E RE V I S I O N S CE R T I F I C A T I O N 13270MEI SD S CR M OC T O B E R 2 5 , 2 0 1 3 AD D E N D U M # 1 11 . 2 7 . 2 0 1 3 1 AD D E N D U M # 2 2 12 . 1 1 . 2 0 1 3 S405S405S405S405 SCALE:S405 3/4" = 1'-0" 1SECTION SCALE:S405 3/4" = 1'-0" 2SECTION SCALE:S405 3/4" = 1'-0" 3SECTION SCALE:S405 3/4" = 1'-0" 4SECTION SCALE:S405 3/4" = 1'-0" 5SECTION SCALE:S405 3/4" = 1'-0" 6SECTION SCALE:S405 3/4" = 1'-0" 7SECTION 1 1 1