Loading...
HomeMy WebLinkAboutA1.1 CONSTRUCTION PLAN.PDFProject Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: PO L L E O S Y S T E M S Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - S u i t e 1 4 4 71 9 H A N O V E R P L A C E COPYRIGHT & OWNERSHIP OF DOCUMENTS N SCALE: 1/128"= 1'-0" KEY PLAN SUITE 144 PEDCOR DESIGN GROUP, L.L.C. A1.1 CONSTRUCTION PLAN MC AJR12/12/2013 STATE RELEASE SET: 12/24/2013 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2013 JAMES R. STUTZMAN, AIA, Carmel, Indiana. N 12. APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL, AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. 13. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 14. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. 15. ALIGN FINISHED FACES. CONSTRUCTION PLAN NOTES: FP1 FP4 FP3 GENERAL CONSTRUCTION NOTES: DIMENSIONS ON FLOOR PLAN ARE FROM FINISHED FACE OF GYPSUM BOARD TO FINISHED FACE OF GYPSUM BOARD UNLESS NOTED OR SHOWN OTHERWISE. DIMENSIONS TO EXTERIOR OR EXISTING WALLS ARE TO THE FINISHED FACE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE IS TO BE VERIFIED WITH THE DESIGNER. DO NOT SCALE DRAWINGS. DIMENSIONS ON ENLARGED PLANS AND ELEVATIONS ARE FROM FINISHED FACE TO FINISHED FACE UNLESS NOTED OTHERWISE. 1. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION.3. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH ARCHITECT ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. 4. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. 5. EXISTING DOORS AND DOOR FRAMES TO BE REUSED ARE TO BE CLEANED AND REINSTALLED AT COMPLETION OF CONSTRUCTION. CONTACT DESIGNER TO REVIEW AND APPROVE DOORS THAT ARE QUESTIONABLE FOR REUSE. 6. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). 7. 8. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS. 9. 10. 11. EXISTING PARTITION TO REMAIN NEW INSULATED WALL PARTITION NEW DEMISING WALL PARTITION WALL LEGEND: NOTES: SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. ALL WALLS ARE TO BE W2 UNLESS NOTED OTHERWISE. WALL AT COLUMN WRAPS TO BE W1. 2. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL UNLESS NOTED OTHERWISE. ALL NEW FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT WALL FINISH AND INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED, A PLAN MUST BE SUBMITTED TO THE ARCHITECT FOR REVIEW FOR AESTHETIC PURPOSES ONLY. 16. SEE SHEET A1.1 FOR DOOR SCHEDULE. 17. ALL PENETRATIONS IN RATED WALL PARTITIONS AND FLOOR SYSTEMS SHALL BE FIRE RATED ASSEMBLIES. SUBMIT PRODUCT DATA AND ASSEMBLY DRAWINGS WITH TEST FILE NUMBERS FOR REVIEW. 18. USE MOISTURE-MOLD RESISTANT GYPSUM WALLBOARD MEETING ASTM D3273 ON ALL WALL SURFACES IN RESTROOMS. INSULATION FOR INTERIOR WALL APPLICATION SHALL BE FORMALDEHYDE-FREE, UNFACED, GLASS-FIBER BLANKET INSULATION IN BATT FORM CONFORMING TO ASTM C 665, TYPE I, WITH THICKNESS TO BE EQUAL OR GREATER THAN THAT STUD THICKNESS OF THE WALL INTO WHICH IS IT INSTALLED. 19. REPAIR AND PATCH ALL FIRE PROOFING ON THE BUILDING SHELL THAT WAS REMOVED DURING CONSTRUCTION. REMOVE FIREPROOFING SPRAY FROM THE DECK AND OTHER ITEMS THAT DO NOT REQUIRE FIRE PROOFING. 20. INSTALL EXISTING REMOVED DOOR. PAINT DOOR AND FRAME TO MATCH NEW DOORS. 40 0 NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. DENOTES AREA NOT IN CONTRACT. 4- 7 / 8 " WALLS TO EXTEND TO STRUCTURAL DECK ABOVE. WITH 5/8" GYPSUM WALL BOARD ONE SIDE.W1 3-5/8" 20 GAUGE METAL STUDS @16" O.C. PROVIDE 3-5/8" INSULATION INSIDE WALL. WALLS TO EXTEND TO STRUCTURAL DECK ABOVE. WITH 5/8" GYPSUM WALL BOARD EACH SIDE.W2 3-5/8" 20 GAUGE METAL STUDS @16"O.C. EXISTING DOOR AND FRAME. SEE BUILDING SHELL PLAN. ALL FURNITURE AND ACCESSORIES ARE TO BE PROVIDED BY THE TENANT. CONSTRUCTION MANAGER IS TO COORDINATE THE INSTALLATION OF THESE ITEMS WITH THE TENANT.W3 6" 20 GAUGE METAL STUDS @16"O.C. WALLS TO EXTEND TO STRUCTURAL DECK ABOVE. PROVIDE 6" INSULATION INSIDE WALL. WITH 5/8" GYPSUM WALL BOARD EACH SIDE.PROVIDE WEATHER STRIPPING AND SEAL AT ALL EXTERIOR DOORS. 4- 7 / 8 " WALLS TO EXTEND TO STRUCTURAL DECK ABOVE. WITH 5/8" GYPSUM WALL BOARD EACH SIDE.W4 3-5/8" 20 GAUGE METAL STUDS @16"O.C. 4- 1 / 4 " 7- 1 / 4 " NEW WALLS TO BE TAPED, SPACKLED, SANDED SMOOTH, WITH ONE (1) COAT OF PRIMER ON UNLEASED SIDE. FP2 REMOVE EXISTING DOOR AND FRAME. SAVE FOR REUSE. UNFINISHED OPENING IN WALL TO REMAIN. FP5 NEW SEMI RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THESE LOCATIONS WITH TOP OF CABINET AT 54" AFF. PAINT TO MATCH ADJACENT WALL SURFACE. CONFIRM QUANTITY OF EXTINGUISHERS WITH FIRE DEPARTMENT. IF EXTINGUISHERS NEED TO BE ADDED VERIFY LOCATIONS WITH THE ARCHITECT. FP6 PROVIDE PLYWOOD BLOCKING FOR TENANT PROVIDED AND INSTALLED TV. FP7 RELOCATE EXISTING CABINETS FROM TENANT’S CURRENT LOCATION IN BUILDING B AS SHOWN AND PROVIDE PLASTIC LAMINATE BASE AND UPPER CABINETS W/SINGLE BOWL SINK AND PULL-OUT FAUCET AND (1) TALL CABINET. NEW CABINET FINISHES TO MATCH EXISTING. SEE ELEVATION 5/A4.1 FOR DETAILS. FP8 RELOCATE EXISTING CABINETS FROM TENANT’S CURRENT LOCATION IN BUILDING B. PROVIDE NEW PLASTIC LAMINATE COUNTER TO FIT NEW CONFIGURATION. SEE ELEVATIONS 6/A4.1 AND 8/A4.1 FOR DETAILS. FP9 PROVIDE 1/4" COLD COPPER LINE W/VALVE FOR TENANT SUPPLIED COFFEE MAKER. FP10 PROVIDE 8’X14’ FIXED GLASS WINDOW WITH INNOVATIVE GLASS, ELECTRICALLY ACTIVATED LC PRIVACY GLASS AND PAINTED HOLLOW METAL FRAME. SEE ELEVATION 7/A4.1 FOR DETAILS. FP11 RECONFIGURATION OF CORRIDOR WALLS AND RELOCATION OF ELECTRICAL PANELS TO BE DONE AS PART OF THE BUILD-OUT OF THE ADJACENT SPACE. FP12 PROVIDE COAT ROD AND SHELF. SEE SECTION 14/A4.1 FOR DETAILS. FP13 PROVIDE ELKAY, WATER COOLER WITH EZH20 BOTTLE FILLING STATION, MODEL EMABF8WS. MOUNT WITH SPOUT AT 33" AFF FOR WHEELCHAIR-USE HEIGHT. FP14 PROVIDE ¾”X4’X4’ FIRE RETARDANT PLYWOOD PHONE BOARD MOUNTED AT 6’-0” AFF TO BOTTOM. PHONE BOARD TO BE PAINTED WITH FIRE RETARDANT PAINT, COLOR TO MATCH ADJACENT WALL. NEW UNINSULATED WALL PARTITION 7' - 0 " 2" 2"3'-0"2" 2"3'-2"2"3'-0"2" 2" 6' - 1 0 " 2" 4' - 0 " 2" 7' - 0 " HARDWARE L = L O C K S E T WORK ROOM104 105 107 SIZE EXISTING DOOR TO REMAIN. RO O M N A M E OP E N I N G NU M B E R 101 WID T H HE I G H T EL E V A T I O N MA T E R I A L TH I C K DOOR MA T E R I A L EL E V A T I O N FRAME REMARKS D O O R S C H E D U L E CONF. RM. MECH/IT D2 S = S T O P CL = C L O S E R 1. DOOR SCHEDULE NOTES: 2. 3. ALL HOLLOW METAL DOORS ARE TO BE PREPPED, PRIMED, AND PAINTED P2 UNLESS NOTED OTHERWISE. D1 ALL NEW WOOD DOORS TO BE FACTORY PRIMED AND FIELD PAINTED P2 UNLESS NOTED OTHERWISE. PROVIDE NEW HARDWARE TO BE: SCHLAGE, ND-SERIES, RHO STYLE, 626 FINISH LEVER HARDWARE. COORDINATE KEYING LOCKSETS WITH THE TENANT. HM D2 HM3'-0"1 3/4" 1 3/4"WD/GL 106 PS,S PS,S 7'-0"3'-0" 7'-0"WOOD D1 D1 PR = P R I V A C Y L O C K 4. PAINT DOOR & FRAME P7; GLASS TO BE CLEAR. 108 CLOSET 109 HM D17'-0"3'-0"1 3/4"WOOD D1 CORRIDOR HM D1 L,CL,S7'-0"3'-0"1 3/4"HM D1 D2 USE RELOCATED DOOR AND HARDWARE. RECEPTION REST ROOM PS = P A S S A G E S E T 100 DOOR AND FRAME TO BE PAINTED. HM D1 PR,CL,S7'-0"3'-0"1 3/4"WOOD D1 EXISTING DOOR TO REMAIN.DOOR AND FRAME TO BE PAINTED. REST ROOM EXISTING DOOR TO REMAIN.DOOR AND FRAME TO BE PAINTED. PS,S 1 A4.1 9 A4.1 1' - 5 1 / 4 " 14 ' - 0 " 21'-5 1/8" 4'-9"4'-0" 5'-2 3/4" 3' - 4 7 / 8 " 8' - 0 " 4' - 0 " 6'-10" 17 ' - 0 " 9'-1 7/8" 5 A4.1 6 A4.1 7 A4.1 8 A4.1 FUTURE WALL FP9 FP7 FP1 FP1 FP6 FP10 FP1 FP1 FP8 FP6 FP6 FP6 FP1 FP12 FP2 FP3 FP4 FP11FP11 FP6 FP8 FP1 FP1 FP1FP1 FP5 FP13 FUTURE WALL DEMO FP14 REST ROOM 107 MECH/IT 106 CONFERENCE ROOM 101 SUITE 144 2,536 SQ. FT. WORK ROOM 104 REST ROOM 105 OPEN OFFICE 102 CLOSET 108 RECEPTION/ COFFEE BAR 100 ELEC. 1-HR FIRE RATED HALLWAY 103 CORRIDOR 109 10 1 10 5 10 7 10 6 104 10 8 109 W1 W1 W1 W1 W4 W3 W4 W4 W4 W1 W1 W1 W1 W1 100 W1 W1 W1 W1 26 24 23 25 N P P.5N.5 SCALE: 1/4" = 1'-0" 1 CONSTRUCTION PLAN A1.1