Loading...
HomeMy WebLinkAboutA1.3 REFLECTED CEILING PLAN.PDFProject Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: PO L L E O S Y S T E M S Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - S u i t e 1 4 4 71 9 H A N O V E R P L A C E COPYRIGHT & OWNERSHIP OF DOCUMENTS N SCALE: 1/128"= 1'-0" KEY PLAN SUITE 144 PEDCOR DESIGN GROUP, L.L.C. A1.3 REFLECTED CEILING PLAN MC AJR12/12/2013 STATE RELEASE SET: 12/24/2013 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2013 JAMES R. STUTZMAN, AIA, Carmel, Indiana. N ELECTRICAL CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. GENERAL CEILING NOTES:CEILING PLAN NOTES: PROVIDE FIRE RATED DAMPERS WHERE REQUIRED AT FIRE RATED WALLS. EMERGENCY STROBES TO BE WHITE AND EMERGENCY LIGHT FIXTURES TO BE WHITE UNLESS NOTED OTHERWISE. COORDINATE IN THE FIELD WITH THE ARCHITECT AND TENANT. INSTALL ACOUSTICAL CEILING PANELS WITH GRAIN/TEXTURE RUNNING IN THE SAME DIRECTION UNLESS NOTED OTHERWISE. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. COORDINATE ALL SWITCHING AND LOCATIONS WITH THE TENANT AND ARCHITECT. LIGHTING TIMER CONTROL SYSTEM IS TO BE PROVIDED TO MEETING ENERGY CODE. CP1 11. 10. 9. 8. 5. 6. 7. 4. 1. 2. 3. HVAC DIFFUSERS AND GRILLES, FIRE SPRINKLERS ARE TO BE CENTERED WITHIN CEILING TILES. REFLECTED CEILING LEGEND: ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE. PROVIDE AND INSTALL TIMER CONTROL SYSTEM. ALL LIGHTS NOT CONTROLLED WITH OCCUPANCY SENSORS ARE TO BE CONTROLLED ON THE TIMER. COORDINATE CIRCUITS AND SWITCHING WITH THE ARCHITECT. PROVIDE A SUSPENDED CEILING CLOUD WITH ARMSTRONG 2X2 DUNE, ANGLED TEGULAR, PRELUDE XL 15/16” GRID, AND ARMSTRONG, AXIOM, 2”, STRAIGHT, WHITE, CLASSIC TRIM. CP3 CP4 12. BLOCKING AND SUPPORTS ARE TO BE PROVIDED FOR ALL CEILING MOUNTED FIXTURES AS NEEDED. 13. LIGHTING CONTROLS. 2' X 2' SUSPENDED CEILING TO BE: ARMSTRONG, 2'X2' DUNE ANGLED TEGULAR, W/ PRELUDE XL 15/16" GRID. EXHAUST GRILLE IN CEILING FOR USE WITH BUILDING'S EXHAUST SYSTEM. FIRE PROOFING IS TO BE REMOVED FROM THE DECK AND OTHER ITEMS IN OPEN CEILING AREAS THAT DO NOT NEED TO BE FIRE PROOFED. 14. PROVIDE A PAINTED DRYWALL BULKHEAD AT 8'-0” WITH 12” DRYWALL EDGE. 15. MEP CONSULTANT TO RUN THE NECESSARY CALCULATIONS TO DETERMINE THAT THE LIGHTING LAYOUT MEETS THE ENERGY CODE. IF IT DOES NOT PLEASE ADDRESS THIS WITH THE ARCHITECT AND THE TENANT TO REVISE LIGHT SELECTIONS AS NEEDED. MEP CONSULTANT IS TO SUBMIT DRAWINGS SHOWING LOCATIONS OF ALL NECESSARY OCCUPANCY SENSORS, HORN STROBES, FIRE PULLS AND EMERGENCY LIGHTS. CP2 GENERAL CEILINGS ARE TO BE OPEN WITH ALL EXPOSED HVAC UNITS, DUCTWORK AND CONDUIT TO BE PAINTED. ALL LIGHT FIXTURES TO BE 3500K COLOR TEMPERATURE. SUSPENDED CEILING SYSTEM TO BE SUSPENDED GRID CEILING - ARMSTRONG 2X2 DUNE, ANGLED TEGULAR WITH PRELUDE XL 15/16” GRID. CP5 EXISTING HVAC HEAT PUMP UNITS TO REMAIN. REPAIR OR REPLACE CONTROLS TO PROVIDE SUITABLE OPERATION. PROVIDE HVAC DISTRIBUTION FROM EXISTING HEAT PUMP UNITS AND PROVIDE NEW UNITS AS NEEDED FOR PROPER COVERAGE. DISTRIBUTION TO CONSIDER THE GROUPING OF SIMILAR ROOMS, LIKE THE RECEPTION AREA AND THE CONFERENCE ROOMS BOTH ON THE EXTERIOR GLASS. REVIEW THE POSSIBLE USE OF BASEBOARD HEATERS AND PROVIDE CONTROLS THAT ALLOW EASY USE BY THE TENANT. CONSIDER THE USE OF DUCT HEATERS FOR THE UNIT SERVING THE BACK AREA OF THE SUITE. HEAT PUMP FANS ARE TO BE TIED TO A BUILDING ELECTRICAL PANEL. ALL OTHER EQUIPMENT IS TO BE TIED TO THE TENANT'S PANEL. CP6 PROVIDE SEPARATE CIRCUIT ON A TIMER FOR THE LIGHTS IN THE RECEPTION AREA.CP7 PROVIDE SEPARATE CIRCUIT ON A TIMER FOR THE LIGHTS IN THE RECEPTION AREA BULKHEAD. CP8 SYMBOL TYPE A1 LIGHT FIXTURE SCHEDULE RECESSED DOWNLIGHT MODEL CREE, 6" LED RECESSED DOWNLIGHT, LR6C-10L, 3500K W/RC6 HOUSING. WATTAGEDESCRIPTION MOUNTING HEIGHT NOTES D LAY-IN FLUORESCENT TROFFER 64W E PHILIPS LIGHTOLIER, SILHOUETTE SD SERIES, SD-2-4-J-54-120V-AL W/T5 LAMPS. CEILING CEILING 54WLINEAR PENDANT FIXTURE 12W MERCURY LIGHTING, 2X2 LAY-IN FLUORESCENT, 54E-2-32-OCT-U6-9-ELB-UNI W/(2) 32W U-6" T8 LAMPS. 8'-0" & 9'-0" AFF TO BOTTOM OF FIXTURE. MERCURY LIGHTING, EDGE LIT LED EXIT SIGNS, MER-ELXTE - RED LETTERS, CLEAR FACE, WHITE HOUSING. EMERGENCY EXIT SIGNS -- MERCURY LIGHTING, LED LOW PROFILE EMERGENCY LIGHT, MER-LEDR1 - WHITE.EMERGENCY LIGHTS -WALL 16. PROVIDE A PAINTED DRYWALL SOFFIT AT 12'-0"WITH 6" DRYWALL LIP. PROVIDE SEPARATE CIRCUIT ON A TIMER FOR THE OPEN OFFICE AREA AND HALLWAY.CP9 PROVIDE CONDUIT EXTENDED TO ABOVE ACCESSIBLE CEILING WITH A SEPARATE CIRCUIT ON A TIMER FOR THE FUTURE OUTDOOR SIGN. CP10 PROVIDE OCCUPANCY SENSORS IN THE CONFERENCE ROOM, WORK ROOM, RESTROOMS, MECH/IT ROOM AND CLOSET. CP11 PROVIDE DIMMERS IN THE CONFERENCE ROOM AND WORK ROOM FOR LIGHTS AS SHOWN.CP12 PROVIDE EXHAUST VENT TIED INTO THE BUILDINGS EXHAUST SYSTEM IN THE RESTROOMS.CP13 RELOCATE THE DUAL-LITE EDGE-LIT EXIT SIGNS AND EMERGENCY LIGHTING REMOVED DURING DEMOLITION. CP14 PROVIDE SMOKE DETECTORS AND LIFE SAFETY ITEMS AS REQUIRED.CP15 CP16 CP17 EXISTING LIGHT AND GRID TO REMAIN. PROVIDE LIGHTING CONTROL TIMER AT THIS LOCATION. OCCUPANCY SENSORS TO BE MOUNTED IN THE CEILING OR ON THE WALL AT A LOCATION THAT SENSES ONLY MOVEMENT FROM INSIDE OF THE ROOM. REVIEW LOCATIONS WITH ARCHITECT. 17. B 24.1WPENDANT LIGHT FIXTURE IMPACT ARCHITECTURAL LIGHTING, mel.o LED PENDANT FIXTURE, P8118, WHITE CONCAVE DIFFUSER, 3500K LED, MATTE ANODIZED FINISH. 12'-6" TO BOTTOM OF FIXTURE. C1 PENDANT DOWNLIGHT CREE, 6" LED PENDANT DOWNLIGHT, LR6C-18L, 3500K W/SC6, CORD MOUNTED.12W 11'-0" TO BOTTOM OF FIXTURE. D1 LAY-IN LED TROFFER 44W CEILINGCREE 2’X2’ ARCHITECTURAL LED TROFFER CR22-32SKA35. F ACCENT PENDANT TRACK FIXTURES LITON, FLEXCURVE TRACK WITH THREE (3) VERTIS PENDANTS LFCX3305-FR-3.12W 11'-0" TO BOTTOM OF TRACK, 8'-0" TO BOTTOM OF FIXTURE. EXISTING CEILINGS TO REMAIN. CONTROLLED BY A SWITCH. REMOVE ALL EXISTING LIGHT FIXTURES, EXIT SIGNS, AND EMERGENCY LIGHTING EXCEPT IN EXISTING REST ROOM AND MECH/IT. SAVE FOR LANDLORD'S REUSE. 18. A RECESSED DOWNLIGHT CREE, 6" LED RECESSED DOWNLIGHT, LR6C-10L-DIMMABLE, 3500K W/RC6 HOUSING.CEILING12W W/ DIMMER. C PENDANT DOWNLIGHT CREE, 6" LED PENDANT DOWNLIGHT, LR6C-18L- DIMMABLE, 3500K W/SC6, CORD MOUNTED.12W 11'-0" TO BOTTOM OF FIXTURE.W/ DIMMER. 2' - 0 " 2' - 0 " 3'-0"7'-6 5/8"7'-6 5/8"7'-6 5/8"5'-2" 3'-8"5'-6 1/8"5'-6 1/8"5'-6 1/8"5'-6 1/8"5'-6 1/8"9'-2 1/8" 7 ' - 6 " 31'-6" 7'-6" 31 ' - 6 " 1' - 9 " 5' - 3 " 5' - 3 " 5' - 3 " 5' - 3 " 5' - 3 " 2' - 1 1 / 4 " 4'-0"4'-0"4'-0"3'-0" 4' - 0 " 4' - 0 " 7' - 0 " 7' - 0 " 9'-0" 1'-4" 3' - 0 " 6' - 7 1 / 4 " 3' - 0 " 4'-0"8'-11 3/4"8'-11 3/4"4'-0" 4"2' - 7 1 / 2 " 5' - 4 1 / 8 " 5' - 4 1 / 8 " 2' - 7 1 / 2 " 1'-9" 3'-9"7'-4 1/8"7'-4 1/8"7'-4 1/8"3'-9" 3' - 0 " 1' - 6 " 1' - 6 " 5' - 3 " 2' - 7 1 / 2 " 9'-0" OPEN 9'-0" 9'-0" 10'-0" OPEN OPEN 11'-0" 12'-0" OPEN 8'-0" OPEN R=32'-23/8"1 A4.2 2 A4.2 CP10 CP1 CP8 CP2 CP6 CP7 CP15 CP14 CP3 CP2 CP6 CP11 CP12 CP15 CP4 CP2 CP6 CP9 CP15 CP14 CP4 CP14 CP2 CP6 CP9 CP15 CP2 CP6 CP9 CP15 CP14 CP5 CP11 CP13 CP11 CP17 CP11 CP16 CP6 CP11 CP12 CP5 CP15 A1 B B B B B B F F F C C C CCC E E D E E C1 A D1 D E E E D A A A A A D D1 D1 C C A1 A1 A1 A1 A1 A1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 26 24 23 25 N P P.5N.5 SCALE: 1/4" = 1'-0" 1 REFLECTED CEILING PLAN A1.3