Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.4 ELECTRICAL_DATA PLAN.PDF
Project Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: PO L L E O S Y S T E M S Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - S u i t e 1 4 4 71 9 H A N O V E R P L A C E COPYRIGHT & OWNERSHIP OF DOCUMENTS N SCALE: 1/128"= 1'-0" KEY PLAN SUITE 144 PEDCOR DESIGN GROUP, L.L.C. A1.4 ELECTRICAL/DATA PLAN MC AJR12/12/2013 STATE RELEASE SET: 12/24/2013 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL ANDUNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, ANDPEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, ORPORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2013JAMES R. STUTZMAN, AIA, Carmel, Indiana. N 7'- 9 " 9'-0" EP8 EP6 EP5 EP5 EP5 EP6 EP5 EP7 EP6 EP6 EP1 EP5 EP8 EP3 EP4 EP2 REST ROOM 107 MECH/IT 106 CONFERENCE ROOM 101 SUITE 144 2,536 SQ. FT. WORK ROOM 104 REST ROOM 105 OPEN OFFICE 102 CLOSET 108 RECEPTION/ COFFEE BAR 100 E E D D D E E EE E E D E E GFI +44" +120" +84" +6 0 " +4 4 " ELEC.HALLWAY 103 CORRIDOR 109 GFI +44" +44" +44" +84" +84" +84" +84" +84" +4 4 " +4 4 " +6 0 " +44" +44" +8 4 " +120" 26 24 23 25 N P P.5N.5 GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX, CONDUIT, AND PULL STRING AT PHONE/DATA LOCATIONS AS INDICATED ON PLANS. EXTEND CONDUIT TO ABOVE ACCESSIBLE CEILING OR TO THE DECK ABOVE. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER,CONSTRUCTION MANAGER, AND/OR DESIGN- BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE UNLESS NOTED OTHERWISE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF TO THE CENTER UNLESS NOTED OTHERWISE. ALL OUTLETS ARE TO BE WHITE UNLESS NOTED OTHERWISE. 7. 9. 6. 5. 4. 3. DUPLEX WALL OUTLET. ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX, CONDUIT AND PULL STRING). +44"HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. EP1 EP2 RELOCATE EXISTING ELECTRICAL PANEL TO THE SERVICE CORRIDOR. LOCATION TO BE DETERMINED. PROVIDE ELECTRICAL FOR TENANT PROVIDED AND INSTALLED UNDER-COUNTER REFRIGERATOR. EP3 EP4 10.ALL PENETRATIONS THROUGH THE DEMISING WALLS BETWEEN TENANTS AND BETWEEN THE TENANT AND THE SERVICE CORRIDOR NEED TO BE FIRE RATED. 11.FIRE ALARM SYSTEM SHALL BE COMPATIBLE AND TIED TO THE EXISTING BUILDING FIRE ALARM SYSTEM. EP5 EP6 PROVIDE ELECTRICAL FOR TENANT PROVIDED AND INSTALLED COFFEE MAKER. PROVIDE ELECTRICAL AND DATA OUTLETS FOR TENANT PROVIDED AND INSTALLED TVS. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. 1. 2.ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. ELECTRICAL JUNCTION BOX PROVIDE ELECTRICAL FOR TENANT PROVIDED AND INSTALLED MICROWAVE. PROVIDE JUNCTION BOX FOR WORKSTATION POWER SUPPLY. COORDINATE THE CONNECTION OF THE FURNITURE’S POWER WHIP. DUPLEX FLOOR OUTLET. EP7 PROVIDE POWER AND CONTROL SWITCH FOR ELECTRICALLY ACTIVATED PRIVACY GLASS. EP8 PROVIDE BUILDING STANDARD KEY FOBS WITH MATCHING ACCESS SETTINGS. KEY FOB FOR SOUTH EXTERIOR DOOR IS TO BE PROVIDED FOR ONLY ONE OF THE DOUBLE DOORS. ADJUST OR REPLACE EXTERIOR STOREFRONT DOOR AS NEEDED SO THAT DOOR CAN BE FOBBED. PHONE/DATA FLOOR OUTLET (BOX, CONDUIT AND PULL STRING). PEDCOR IT TO PROVIDE WIRING FROM THE TENANT'S PHONE BOARD TO EACH VOICE/DATA DROP. CONNECTIONS ARE TO BE INCLUDED AT EACH DROP. 8. D DENOTES EXISTING OUTLETS TO BE REMOVED AND DRYWALL PATCHED. E DENOTES EXISTING OUTLETS TO REMAIN. EP8 PROVIDE BUILDING STANDARD KEY FOBS WITH MATCHING ACCESS SETTINGS. KEY FOB FOR SOUTH EXTERIOR DOOR IS TO BE PROVIDED FOR ONLY ONE OF THE DOUBLE DOORS. ADJUST OR REPLACE EXTERIOR STOREFRONT DOOR AS NEEDED SO THAT DOOR CAN BE FOBBED. SCALE: 1/4" = 1'-0" 1 ELECTRICAL/DATA PLAN A1.4