3" NatureScape Wall System Structural Capacity due to Combined Compressive and Lateral
Loading
To: Whom it May Concern
'The referenced structure has been evaluated per your request to determine it's structural
adequacy.
The live, dead. snow and wind loads as provided by the customer are as follows:
Live = 10 psf
Dead = 5.88 psf
Snow = 30 psf
Area Wind speed = 90 mph, exposure B
Based on the information provided the referenced structure is suffcent to support the total
combined loads provided that a 3" x 3" x 0.125" 6063-T6 aluminum post be installed to the
interior or ex'tenor of the currently installed doge beam support post. The post should be
attached with # 10 screws 6" from the ends and at 12" centers as shown in Detail A or B.
The determination of the structural adequacy of the existing residence, roof (and
and any walls other than PGT provided components of the sunroom is the res lity
others.