HomeMy WebLinkAbout05050084-Correspondence INDUSTRIES CUSTOM WINDOWS DooRs & PAT 0 P, OOMS October 13, 2005 Reference:/l~rk & Angola Bochan Residence 10388 Bdar Creek Place Carmel. In 46033 ]070 TECHNOLOGY DRiV NOKOMIS, FtORIDA 34275 /~O BOX 1529 NO~(OM[S, FLOR]DA 34274 TOLL FREE: 800-282-6019 PHON[: 941'480- FAX: 800-477 ~655 www ~tindustries,com 3" NatureScape Wall System Structural Capacity due to Combined Compressive and Lateral Loading To: Whom it May Concern 'The referenced structure has been evaluated per your request to determine it's structural adequacy. The live, dead. snow and wind loads as provided by the customer are as follows: Live = 10 psf Dead = 5.88 psf Snow = 30 psf Area Wind speed = 90 mph, exposure B Based on the information provided the referenced structure is suffcent to support the total combined loads provided that a 3" x 3" x 0.125" 6063-T6 aluminum post be installed to the interior or ex'tenor of the currently installed doge beam support post. The post should be attached with # 10 screws 6" from the ends and at 12" centers as shown in Detail A or B. The determination of the structural adequacy of the existing residence, roof (and and any walls other than PGT provided components of the sunroom is the res lity others. Please advise if there are any further questions or requirements. "~ Sincerely ~ 3x3 oost.owg Model. 10/13/2005 11 '07:21 AM, r)g, HPLJB000.pc3,1 lx17.1:4 m