HomeMy WebLinkAbout0003.98 MiscellaneousE BUILDING FILE'REPORT SCHULILER Builder's File: DAVEN186.BLG Date: December 16 1997 Page 1 Builder Information Home Builder Name: DAVIS HOMES Model Name or Number: DAVENTRY Development Name: SHELBORNEVILLAGE Property Address: LOT #186 Energy Analysis Info Insulation Contractor Name: OVERHEAD DOOR INSUL. DIV. Telephone Number: (317) 842-7444 Building Plan Date: 12/11/97 General Design Characteristics House Type: One Story Foundation Type: Slab Conditioned Floor Area: 1584.00 Number of Bedrooms: 3 Conditioned Floor Area Over Garage: 0.00 % Of Total Floor Area Heated First Mid Second Third Basement Level Level Level Level Distribution of Cond Floor Area(%) 100.0 Heated First Mid Second Third Characteristics of Each Floor Basement Level Level Level Level Number of Corners 6 Percent Open to Floor Above 0.0 Nominal Flat Ceiling Height 9.0 Percent CathedralCeiling 0.5 Schuller International, Inc.. Building Insulation, Division P.O. Box 5108 Denver, CO 80217-5108. For information on the Performance Home Total Insulation System, call1-800-654-3103. This information doesnot constitute any war ianty of energy cost or savings. REM/Gold v2.33 (c)1996 Architectural Energy Corporation. Boulder, CO. BUILDING FILE REPORT DAVEN186.BLG Page 2 Insulation Level Specify below... Ceiling(Attic Above): 38.0 Cathedral Ceiling: 38.0 Rim/Band Joist: 13.0 Frame Wall(Frame Cavity): 13.0 Frame , Wall(Continuous): 4.4 Masonry Wall 0.0 Foundation Wall(Cavity): 0.0 Foundation Wall(Continous): 5.5 Frame Floor: 19.0 Duct: SuperDuct/Flex, R4.2 Infiltration Rate(ACH): 0.75 Wall Construction Type: Mixed... Window Type Double/LoE - Vinyl Window U-Value: 0.36 Window SHGC: 0.45 Window Area(excluding fnd walls): 250.0 square feet Number of Non -Glass Exterior Doors: 2 Average Slab Depth Below Grade Basement: 0.0 First Level: 1.0 Heating System Type: Fuel -fired air distribution. Heating Fuel Type: Gas Cooling System Type: Air conditioner Duct Location: Attic -under insul Domestic Hot Water Fuel Type: Gas uller International, Inc. Building Insulation Division P.O. Box,5108 Denver, CO 80217-5108. For information on the Performance Home Total Insulation System' call 1-800-654-3103. This information does not constitute .any warranty, of energy cost or savings. REM/Goldv2.33 (c)1996 Architectural Energy. Corporation, Boulder, CO. Si(iHiUiLiLiEiR 1993 MEC OVERALL BUILDING Uo.COMRLIANCE Date: December 16 1997 Building File:, DAVEN186.BLG Home.Builder: DAVIS HOMES Weather Site: Indianapolis, IN Model Name or Number: DAVENTRY Degree Days, H/C: 5653/378 Insulation Contractor: OVERHEAD DOOR INSUL bIV. Energy Costs: Indiana Gas Contractor's Telephone: (317) 842-7444 Elements Insulation Levels 1993 MEC As Designed Roofs/Geilings(U-Value) 0.028 0.026 Above -Grade Walls (U-Value): 0.131 0.113 Basement Walls (U-Value): 0.088 0.127 OVERALL Uo: 0.679 0.072 This home meets the overall thermal performance requirements of the 1993 Model Energy Code based on 5653 heating degree-days. (Section 502, Model Energy Code, 1993 edition). Building. Elements Cavity Ins. Contin. Ins Frame R-Value R-Value Spacing Uo Area Roof/Ceilings Roof 38.0 0.0 24.0" o.c. 0.025 728.6 Roof 38.0 0.0 24.0" o.c. 0.027 901.5 Above-GradeWal Is Wall 13.0 4.4 Wood, 2x4, 16" o.c. 0.057 962.7 Wall 13.0 4.4 Wood, 2x4, 16" o.c. 0.056 320.9 Window n/a n/a n/a 0.360 46.9 Window n/a n/a n/a 0.360 46.9 Window n/a n/a n/a 0.360 93.8 Window n/a n/a n/a 0.360 15.6 Window n/a n/a n/a 0.360 15.6 Window n/a n/a n/a 0.360 31.2 Door n/a 2.0 n/a 0.372 30.0 Door n/a 2.0 n/a 0.372 10.0 Basement Walls Wall 0.0 5.5 None 0.127 174.2