HomeMy WebLinkAbout0003.98 MiscellaneousE
BUILDING FILE'REPORT
SCHULILER
Builder's File: DAVEN186.BLG Date: December 16 1997 Page 1
Builder Information
Home Builder Name:
DAVIS HOMES
Model Name or Number:
DAVENTRY
Development Name:
SHELBORNEVILLAGE
Property Address:
LOT #186
Energy Analysis Info
Insulation Contractor Name:
OVERHEAD DOOR INSUL. DIV.
Telephone Number:
(317) 842-7444
Building Plan Date:
12/11/97
General Design Characteristics
House Type:
One Story
Foundation Type:
Slab
Conditioned Floor Area:
1584.00
Number of Bedrooms:
3
Conditioned Floor Area Over Garage:
0.00 % Of Total Floor Area
Heated
First
Mid
Second
Third
Basement
Level
Level
Level
Level
Distribution of Cond Floor Area(%)
100.0
Heated
First
Mid
Second
Third
Characteristics of Each Floor
Basement
Level
Level
Level
Level
Number of Corners
6
Percent Open to Floor Above
0.0
Nominal Flat Ceiling Height
9.0
Percent CathedralCeiling
0.5
Schuller International, Inc.. Building Insulation, Division P.O. Box 5108 Denver, CO 80217-5108.
For information on the Performance Home Total Insulation System, call1-800-654-3103.
This information doesnot constitute any war ianty of energy cost or savings.
REM/Gold v2.33 (c)1996 Architectural Energy Corporation. Boulder, CO.
BUILDING FILE REPORT
DAVEN186.BLG
Page 2
Insulation Level
Specify below...
Ceiling(Attic Above):
38.0
Cathedral Ceiling:
38.0
Rim/Band Joist:
13.0
Frame Wall(Frame Cavity):
13.0
Frame , Wall(Continuous):
4.4
Masonry Wall
0.0
Foundation Wall(Cavity):
0.0
Foundation Wall(Continous):
5.5
Frame Floor:
19.0
Duct:
SuperDuct/Flex, R4.2
Infiltration Rate(ACH):
0.75
Wall Construction Type: Mixed...
Window Type
Double/LoE - Vinyl
Window U-Value:
0.36
Window SHGC:
0.45
Window Area(excluding fnd walls): 250.0 square feet
Number of Non -Glass Exterior Doors: 2
Average Slab Depth Below Grade
Basement: 0.0
First Level: 1.0
Heating System Type: Fuel -fired air distribution.
Heating Fuel Type: Gas
Cooling System Type: Air conditioner
Duct Location: Attic -under insul
Domestic Hot Water Fuel Type: Gas
uller International, Inc. Building Insulation Division P.O. Box,5108 Denver, CO 80217-5108.
For information on the Performance Home Total Insulation System' call 1-800-654-3103.
This information does not constitute .any warranty, of energy cost or savings.
REM/Goldv2.33 (c)1996 Architectural Energy. Corporation, Boulder, CO.
Si(iHiUiLiLiEiR
1993 MEC OVERALL BUILDING Uo.COMRLIANCE
Date:
December 16 1997
Building File:,
DAVEN186.BLG
Home.Builder:
DAVIS HOMES
Weather Site:
Indianapolis, IN
Model Name or Number:
DAVENTRY
Degree Days, H/C:
5653/378
Insulation Contractor:
OVERHEAD DOOR INSUL bIV.
Energy Costs:
Indiana Gas
Contractor's Telephone:
(317) 842-7444
Elements
Insulation Levels
1993 MEC As Designed
Roofs/Geilings(U-Value) 0.028
0.026
Above -Grade Walls (U-Value): 0.131
0.113
Basement Walls (U-Value): 0.088
0.127
OVERALL Uo: 0.679
0.072
This home meets the overall thermal performance requirements of the 1993 Model Energy Code
based on 5653 heating degree-days. (Section 502, Model Energy Code, 1993 edition).
Building. Elements
Cavity Ins.
Contin. Ins
Frame
R-Value
R-Value
Spacing
Uo
Area
Roof/Ceilings
Roof
38.0
0.0
24.0" o.c.
0.025
728.6
Roof
38.0
0.0
24.0" o.c.
0.027
901.5
Above-GradeWal Is
Wall
13.0
4.4
Wood, 2x4, 16" o.c.
0.057
962.7
Wall
13.0
4.4
Wood, 2x4, 16" o.c.
0.056
320.9
Window
n/a
n/a
n/a
0.360
46.9
Window
n/a
n/a
n/a
0.360
46.9
Window
n/a
n/a
n/a
0.360
93.8
Window
n/a
n/a
n/a
0.360
15.6
Window
n/a
n/a
n/a
0.360
15.6
Window
n/a
n/a
n/a
0.360
31.2
Door
n/a
2.0
n/a
0.372
30.0
Door
n/a
2.0
n/a
0.372
10.0
Basement Walls
Wall
0.0
5.5
None
0.127
174.2