C104 SWPPP DETAILSDETAIL OF INLET SEDIMENT CONTROL DEVICE VELCRO CLOSURE LIFT STRAPS USED FOR EASY MOVEMENT AND INSPECTION OF UNIT STORM SEWER GRATE R STORM SEWER GRATE Ò Ò Mechanical Properties Test Method Units MARV Grab Tensile Strength ASTM D 4632 kN (lbs)1.62 (365) X 0.89 (200) Grab Tensile Elongation ASTM D 4632 %24 X 10 Puncture Strength ASTM D 4833 kN (lbs)0.40 (90) Mullen Burst Strength ASTM D 3786 kPa (psi)3097 (450) Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.51 (115) X 0.33 (75) UV Resistence ASTM D 4355 %90 Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40) Flow Rate ASTM D 4491 1/min/m (gal/min/ft )5907 (145) Permittivity ASTM D 4491 Sec 2.1-1 22 Ò Ò RDANDY BAG SILT FENCE INLET PROTECTION INSTALLATION 1.DIG AN EIGHT-INCH DEEP, FOUR-INCH WIDE TRENCH AROUND THE PERIMETER OF THE INLET. 2.IF USING PRE-ASSEMBLED GEOTEXTILE FABRIC AND POSTS, DRIVE THE POSTS INTO THE SOIL, TIGHTLY STRETCHING THE GEOTEXTILE FABRIC BETWEEN POSTS AS EACH IS DRIVEN. (POSTS MUST BE PLACED ON THE INLET SIDE OF THE ANCHOR TRENCH WITH THE GEOTEXTILE FABRIC ON THE SIDE OF THE TRENCH FARTHEST FROM THE INLET.) NOTE:IF ASSEMBLING THE GEOTEXTILE FABRIC AND POSTS ON-SITE, DRIVE THE POSTS INTO THE SOIL AND THEN SECURE THE GEOTEXTILE FABRIC TO THE POSTS BY PLACING A PIECE OF LATHE OVER THE FABRIC AND FASTENING IT TO THE POST (STRETCHING THE FABRIC BETWEEN POSTS AS IT IS FASTENED). 3.USE THE WRAP JOIN METHOD WHEN JOINING POSTS. 4.PLACE THE BOTTOM 12 INCHES OF GEOTEXTILE FABRIC INTO THE EIGHT-INCH DEEP TRENCH, LAYING THE REMAINING FOUR INCHES IN THE BOTTOM OF THE TRENCH AND EXTENDING AWAY FROM THE INLET. 5.BACKFILL THE TRENCH WITH SOIL MATERIAL AND COMPACT IT IN PLACE. 6.BRACE THE POSTS BY NAILING BRACES INTO EACH CORNER POST OR UTILIZE RIGID PANELS TO SUPPORT FABRIC. NOTE: IN SITUATIONS WHERE STORM WATER MAY BYPASS THE STRUCTURE, EITHER: SET THE TOP OF THE GEOTEXTILE FABRIC FILTER AT LEAST SIX INCHES LOWER THAN THE GROUND ELEVATION ON THE DOWN-SLOPE SIDE OF THE STORM DRAIN INLET, BUILD A TEMPORARY DIKE, COMPACTED TO SIX INCHES HIGHER THAN THE FABRIC, ON THE DOWN-SLOPE SIDE OF THE STORM DRAIN INLET, AND/OR USE IN CONJUNCTION WITH EXCAVATED DROP INLET PROTECTION. MAINTENANCE _ INSPECT DAILY. _ INSPECT GEOTEXTILE FABRIC AND MAKE NEEDED REPAIRS IMMEDIATELY. _ REMOVE SEDIMENT FROM POOL AREA TO PROVIDE STORAGE FOR THE NEXT STORM EVENT. AVOID DAMAGING OR UNDERCUTTING FABRIC DURING SEDIMENT REMOVAL. _ WHEN CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE SEDIMENT, PROPERLY DISPOSE OF ALL CONSTRUCTION MATERIAL, GRADE AREA TO THE ELEVATION OF THE STORM DRAIN INLET TOP, THEN STABILIZE IMMEDIATELY. REFERENCED IN CHAPTER 7 PAGE 153-157 IN THE INDIANA STORM WATER QUALITY MANUAL. SECURELY FASTEN OVERLAPPING ENDS OF SILT FENCE MATERIAL TO ADJACENT STAKES WITH THREE WIRE TIES OR OTHER FASTENERS ATTACH THE WOVEN WIRE FENCE TO EACH POST WITH THREE WIRE TIES OR OTHER FASTENERS SILT FENCE MATERIAL TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH THREE TIES SPACED AT 3" ON CENTER 4"x8" TRENCH STORM SEWER GRATE REINFORCED CORNERS MANAGEABLE 2 FOOT CONTAINMENT AREA LIFT STRAPS OPTIONAL OVERFLOW PORTS DUMPING STRAPS STORM INLET DETAIL OF INLET SEDIMENT CONTROL DEVICE Ô Ô Ô Grab Tensile Strength ASTM D 4632 kN (lbs)1.78 (400) x 1.40 (315) Grab Tensile Elongation ASTM D 4632 %15 x 15 Puncture Strength ASTM D 4833 kN (lbs)0.67 (150) Mullen Burst Strength ASTM D 3786 kPa (psi)5506 (800) Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.67 (150) x 0.73 (165) UV Resistence ASTM D 4355 %90 Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40) Flow Rate ASTM D 4491 1/min/m (gal/min/ft )2852 (70) Permittivity ASTM D 4491 Sec 0.90-1 22 Ô Grab Tensile Strength ASTM D 4632 kN (lbs)1.62 (365) X 0.89 (200) Grab Tensile Elongation ASTM D 4632 %24 X 10 Puncture Strength ASTM D 4833 kN (lbs)0.40 (90) Mullen Burst Strength ASTM D 3786 kPa (psi)3097 (450) Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.51 (115) X 0.33 (75) UV Resistence ASTM D 4355 %90 Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40) Flow Rate ASTM D 4491 1/min/m (gal/min/ft )5907 (145) Permittivity ASTM D 4491 Sec 2.1-1 22 Ô RU N O F F BLOCK AND AGGREGATE INLET SEDIMENT DEVICE INSTALLATION 1.EXCAVATE THE FOUNDATION FOR THE CONCRETE BLOCKS ON LEVEL GRADE AND AT LEAST TWO INCHES BELOW THE TOP OF THE STORM DRAIN INLET. 2.PLACE THE BOTTOM ROW OF CONCRETE BLOCKS AROUND THE PERIMETER OF THE STORM DRAIN. LAY BLOCKS WITH OPENINGS FACING UP, ABUTTING THE BLOCKS FIRMLY TOGETHER AND OVERLAPPING THE CORNERS. 3.IF NECESSARY, SUPPORT THE BLOCKS BY DRIVING SHARPENED 2 X 4 INCH WOOD STUDS OR REBAR (NOT MORTAR) THROUGH THE BLOCK OPENINGS AND INTO THE UNDERLYING SOIL. 4.ON EACH SIDE OF THE BOTTOM ROW, TURN ONE CONCRETE BLOCK WITH ITS OPENINGS FACING HORIZONTALLY TO ALLOW FOR DEWATERING. 5.PLACE HARDWARE CLOTH OVER THE OPENINGS TO HOLD THE AGGREGATE IN PLACE. 6.PLACE THE FILTER MEDIUM (INDOT CA NO. 5 AGGREGATE) AROUND THE OUTSIDE OF THE CONCRETE BLOCKS TO CONTROL DRAINAGE RATE; LIMIT FILTER MEDIUM SIDE SLOPES TO 2:1 RATIO OR FLATTER. NOTE: IN SITUATIONS WHERE STORM WATER MAY BYPASS THE STRUCTURE, EITHER: _ SET THE TOP OF THE CONCRETE BLOCKS AT LEAST SIX INCHES LOWER THAN THE GROUND ELEVATION ON THE DOWN-SLOPE SIDE OF THE STORM DRAIN INLET, _ BUILD A TEMPORARY DIKE, COMPACTED TO SIX INCHES HIGHER THAN THE CONCRETE BLOCKS, ON THE DOWN-SLOPE SIDE OF THE STORM DRAIN INLET, AND/OR _ USE IN CONJUNCTION WITH EXCAVATED DROP INLET PROTECTION (SEE EXCAVATED DROP INLET PROTECTION ON PAGE 145). MAINTENANCE _ INSPECT DAILY. _ REMOVE SEDIMENT AND DEBRIS AND MAKE NEEDED REPAIRS IMMEDIATELY. _ WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE AND PROPERLY DISPOSE OF ALL CONSTRUCTION MATERIAL AND SEDIMENT, THEN STABILIZE. CONCRETE BLOCKS (ONE CONCRETE BLOCK, IN BOTTOM ROW OF BLOCKS ON EACH SIDE OF STRUCTURE LAID HORIZONTALY TO ALLOW FOR DEWATERING DETAIL OF INLET SEDIMENT CONTROL DEVICE WITH CURB FILTER STORM GRATE LIFT STRAPS CURB FILTER OPTIONAL OUTFLOW PORTS DUMPING STRAPS CURB OPENING REINFORCED CORNERS MANAGEABLE 2 FOOT CONTAINMENT AREA Ô Ô Ô Grab Tensile Strength ASTM D 4632 kN (lbs)1.78 (400) x 1.40 (315) Grab Tensile Elongation ASTM D 4632 %15 x 15 Puncture Strength ASTM D 4833 kN (lbs)0.67 (150) Mullen Burst Strength ASTM D 3786 kPa (psi)5506 (800) Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.67 (150) x 0.73 (165) UV Resistence ASTM D 4355 %90 Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40) Flow Rate ASTM D 4491 1/min/m (gal/min/ft )2852 (70) Permittivity ASTM D 4491 Sec 0.90-1 2 Ô Grab Tensile Strength 1.62 (365) X 0.89 (200) Grab Tensile Elongation 24 X 10 Puncture Strength 0.40 (90) Mullen Burst Strength 3097 (450) Trapezoid Tear Strength 0.51 (115) X 0.33 (75) UV Resistence 90 Apparent Opening Size 0.425 (40) Flow Rate 5907 (145) Permittivity 2.1 Ô 2 ASTM D 4632 ASTM D 4632 ASTM D 4833 ASTM D 3786 ASTM D 4533 ASTM D 4355 ASTM D 4751 ASTM D 4491 ASTM D 4491 kN (lbs) % kN (lbs) kPa (psi) kN (lbs) % Mm (US Std Sieve) 1/min/m (gal/min/ft ) Sec -1 2 2 C104 SW P P P D E T A I L S w1 5 0 4 8 3 - C 1 0 4 s w p p p d e t EDGE OF PAVEMENT RUNO F F RUNOFF RU N O F F RU N O F F RUNOFF EDGE OF PAVEMENT FOR SAG INLETS LOCATIONS (NO SCALE) MAINTENANCE - INSPECT DAILY. - REMOVE ACCUMULATED SEDIMENT FROM PAVED AREA (DO NOT FLUSH WITH WATER) AFTER EACH STORM EVENT. DEPOSIT SEDIMENT IN AN AREA WHERE IT WILL NOT RE-ENTER THE PAVED AREA OR STORM DRAINS. - INSPECT FOR DAMAGE BY VEHICULAR TRAFFIC AND REPAIR IF NEEDED. _ WHEN CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE SEDIMENT, PROPERLY DISPOSE OF ALL CONSTRUCTION MATERIAL, GRADE AREA TO THE ELEVATION OF THE STORM DRAIN INLET TOP, THEN STABILIZE IMMEDIATELY. (NO SCALE) FOR NON PAVED AREAS (NO SCALE) POSTS: 2 X 4 WOODEN STAKE FENCE: WOVEN WIRE, 14-1/2 GA., 6" MAX. MESH OPENING FABRIC: IN ACCORDANCE WITH ASTM D 6461 LATEST EDITION. GEOTEXTILE FABRIC LAID ON DOWN-SLOPE SIDE AND BOTTOM OF TRENCH EXTEND WIRE FENCE A MIN. OF 8" INTO GROUND WOVEN WIRE FENCE WITH SILT FENCE MATERIAL COVER CROSS BRACE 1"x2" or 1"x3" 36" MAX. (TYP.) DROP INLET WITH GRATE 12 " M I N . 18 " M A X . 2"x2" OR 2"X4" WOOD FRAME 2"x2" or 2"x4" STAKE 5' MIN. OVERLAP DANDY BAG (NO SCALE) (NO SCALE) Ô Ô (NO SCALE) INLET AGGREGATE INDOT #5 RUNOFF CONCRETE BLOCK LAID HORIZONTAL FOR DEWATERING FILTERED WATER HARDWARE CLOTH FINISHED GRADE 2:1 SLOPE OR FLATTER AGGREGATEGRATED INLET WIRE MESH COCONUT MAT INLET PROTECTION PLAN SECTION RE V I S I O N S A N D I S S U E S Pa r t o f t h e S E / 4 o f S e c t i o n 2 3 , T o w n s h i p 1 8 N o r t h , R a n g e 3 E a s t , C l a y T o w n s h i p , H a m i l t o n C o u n t y , I n d i a n a W15.0483 PR E P A R E D F O R : 12 4 2 W E S T 1 3 6 T H S T R E E T , C A R M E L , I N 4 6 0 3 2 PROJECT NO. SHEET NO. CH E C K E D B Y : DR A W N B Y : RL W DE S I G N E D B Y : DW G N A M E : PR O J E C T N O . : W1 5 . 0 4 8 3 DA T E BY 05 . 1 9 . 2 0 1 6 SS R DA T E : RL W EN G I N E E R S 31 7 | 8 4 6 - 6 6 1 1 80 0 | 4 5 2 - 6 4 0 8 31 7 | 8 4 3 - 0 5 4 6 fa x W E I H E La n d S u r v e y i n g | C i v i l E n g i n e e r i n g La n d s c a p e A r c h i t e c t u r e AL L A N H . W E I H E , P . E . , L . S . - F O U N D E R 10 5 0 5 N . C o l l e g e A v e n u e In d i a n a p o l i s , I n d i a n a 4 6 2 8 0 we i h e . n e t Know what's below. before you dig.Call R TR A D E R ' S P O I N T C H U R C H O F C A R M E L SU B M I T T E D F O R I N I T I A L R E V I E W 12 . 1 8 . 2 0 1 5 ML T THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD AREA AS ESTABLISHED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY - NATIONAL FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY SCALE ON FLOOD INSURANCE RATE #18057C207G, DATED NOVEMBER 19, 2014 FLOOD STATEMENT STEVEN SCOTT RUCKER P.E. 11300279 SU B M I T T E D F O R T A C R E V I S I O N S 03 . 1 4 . 2 0 1 6 ML T NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT NOTE SU B M I T T E D F O R D R A I N A G E A P P R O V A L 04 . 2 0 . 2 0 1 6 ML T RE V I S E D F O R D R A I N A G E A P P R O V A L 05 . 1 2 . 2 0 1 6 ML T FI N A L C O N S T R U C T I O N P L A N S 05 . 1 9 . 2 0 1 6 ML T