Loading...
L300 IRRIGATED AREAS PLANRain SensorController inExterior Wall Mount CabinetPoint of ConnectionWater room to containmeter and backflow preventorManual ValveMainline4" Sleeve4" SleevePoint of ConnectionBackflow Preventor inExterior EnclosureRain SensorController inExterior WallMountCabinetFirehouse SquareCarmel, IndianaPREPARED FORPROJECTNORTH©2020 Anderson + Bohlander, LLC1054 Virginia Ave, Suite 210Indianapolis, Indiana 46201www.andersonbohlander.comSCALE :ADLS Set03/11/2020REVISIONSNo.DateIssueDRAWN BY:CHECKED BY:SHEET TITLESHEET NUMBERCARJDAOnXW East1828 Central AvenueIndianapolis, IN 46202 R EGI STEREDSTATE OF INDIA NA LA21400024LANDSCAPEARCHIT ECT C R AI GA.ROWE01 05/12/2020 Updates per Review02 05/28/2020 Parking Islands/Transformers03 07/13/2020 Bike Racks & Planting Revs1" = 40'-0"20'-0" 40'-0" 80'-0"L300IRRIGATED AREAS PLANNOTES - IRRIGATIONIrrigated Areas Plan - Overall011.Concrete contractor responsible for installation of sleeves prior to theinstallation of any paved surfaces. Concrete contractor responsible to boreany pipe that was not sleeved at their own expense. Preliminary sleevelocations shown on plan for anticipated path of mainline, coordinate withIrrigation Contractor shop drawings prior to installing sleeves. Refer to sleevedetail 02 sheet L300. Concrete contractor to provide irrigation contractorwith as-built plan showing all installed sleeve locations.2.Comply with all state and local irrigation codes and regulations.3.Secure and pay for all permits, fees and inspections necessary for executionof this work.4.Obtain owner representative's approval of pipe trench and line layout priorto installation.5.Irrigate all areas indicated on plan.6.Irrigation contractor to size point of connection, pipe size and all equipmentas part of shop drawing submittal.7.Contractor to field test water pressure and notify owner of results prior tostarting work. Irrigation contractor responsible for providing booster pumpand enclosure if required.8.Separate Irrigation systems will be installed on each side of Veteran's Way.Each system will have independent meters, backflow preventers, andcontrols.9.Irrigation contractor to confirm all quantities. Supply sufficient quantities toprovide complete and functional irrigation.10.Submit shop drawings for a complete and functional irrigation system.System to provide 100% head to head coverage, within an area shown onirrigation plan. Per plumbing plans & water source, Irrigation zones shall notexceed 35 gallons per minute.11.Irrigation contractor is to verify the exact location of all existing andproposed utilities and take necessary precautions and care to protect utilitieswhile installing irrigation system. Contractor to coordinate all constructionwith the appropriate utility company and shall be responsible for anydamages to utility lines.12.Locate all valves and quick couplers on the inside edge of all shrub bedswhere practical. Install valve boxes for both quick couplers and valves. Allvalve boxes shall have a gravel base.13.Flush all lines before installing sprinkler heads.14.Irrigation contractor to provide backflow preventor in a locking metalenclosure.15.Supply controller in locking exterior mounted case, coordinate with ownerfor location.16.Provide quick couplers for seasonal winterization at ends of each run ofmainline pipe.17.Ensure that sprinkler heads do not spray buildings, walls, sidewalks or streets.18.Provide owner with as-built drawings.19.Coordinate with other trades.LEGEND - IRRIGATIONIrrigation AreasRain Shut-off SensorRainbird Rain CheckCoordinate Location with OwnerController RainbirdESP-LX ModularCoordinate Location with OwnerMainlinePoint of Connection& MeterBackflow PreventerIsolation ValveManual Brass Ball ValveIrrigation Sleeve4" Schedule 40 PVCRefer to Detail 02 - Sheet 300To be installed by hardscape contractor.Irrigation Sleeve Pipe02Scale: N.T.S.d-IRR-sleeveMark Edge of Pavement at SleeveLocation. Mark side of pavementonly, do not apply mark to top ofpavement surface.Sleeve Pipe - Schedule 40Seal End of Sleeve Pipe with DuctTapeExtend Sleeve Pipe 12" Minimumpast pavement edgePaving (Varies)Note: Use 4" Sleeve for combinedmainline, lateral and wire areas.Use 2" Sleeve for single lateral lineonly areas. Drip line should not berun though sleeves, always use asolid lateral line. Provide marked upas-built plan to owner and generalcontractor for coordination.