Loading...
Frank E. Irish, Inc/CPDFrank E. Irish, Inc. Police Dept.-2001 Maintenance - Heating/AC Systems - Buildings # 11, # 15, #30 Appropriation #1110-515-01; P.O. #05978 Contract Not To Exceed $4,200.00 APPROVED, AS IO RIDER TO GOODS AND SERVICES AGREEMENT This Rider to the Goods and Services Agreement ("Agreement") executed by Frank E. Irish, Inc. ("Vendor") and the City of Carmel, Indiana ("City") on November 5, 1997 (City Contract No. ~d Safety, and Vendor on this _ WHEREAS, on January 1, 2001, the City instituted a mandatory "purchase order system" for the City's purchase of all goods and services exceeding Two Hundred Fifty Dollars ($250.00) in value; and WHEREAS, in order to operate under this "purchase order system," every City contract must contain an estimate of the cost of providing goods and services to the City pursuant to such contract, and the City must rely on this estimate when encumbering sufficient monies to pay for same. NOW, THEREFORE, THE PARTIES AGREE AS FOLLOWS: 1. The above Recitals are incorporated herein as though they were fully set forth below. 2. Vendor estimates that the total cost for all goods and services ("Goods and Services") provided to City pursuant to the Agreement during calendar year 2001, which consists of labor and materials to provide seasonal maintenance on heating and cooling systems at Buildings #1 I, #15, and #30, will not exceed $4,200.00 (the "Estimate"). 3. City agrees to prepare a purchase order setting aside the sum of the Estimate to pay for the Goods and Services provided during the time period covered by the Estimate, and to indicate budget appropriation number 1110-515-01 as being that from which such Goods and Services are to be paid on said purchase order. 4. Vendor agrees to notify City, in writing, when the total cost for all Goods and Services provided to City by Vendor pursuant to the Agreement during the time period covered by an Estimate reaches the amount of the Estimate. 5. Vendor agrees that it will not provide any Goods or Services to City during the time period covered by an Estimate if the provision of same would cause the total cost of the Goods and Services provided to City during such time period to exceed the Estimate amount, without prior written City approval. 6. This Rider shall continue in effect from year to year, unless earlier modified or terminated in writing by the parties hereto, except that this Rider shall automatically terminate on the date on which the Agreement itself is terminated. 7. The terms of this Rider shall supercede any contrary terms or conditions contained in the Agreement. All Agreement terms and conditions not so affected shall remain in full force and effect, are incorporated herein by this reference and shall apply to this Rider as well. Frank E. Irish, Inc. Police Dept.-2001 Maintenance - Heating/AC Systems - Buildings #11, #15, #30 Appropriation #1110-515-01; P.O. #05978 Contract Not To Exceed $4,200.00 8. The effective date of this Rider shall be the date on which it is last signed by a party hereto. 1N WITNESS WHEREOF, the parties hereto have made and executed this Rider as follows: CITY OF CARMEL, INDIANA ("CITY") By and through its Board of Public Works and Safety ary ~urke, Member Date: ] c9~'/~ '-- J Date: FRANK E. IRISH, INC. ("VENDOR") BY: RICHARD S. IRISH Printed Name CONTROLLER Title FID/SSN: 35-1083972 Date: 12/03/01 ATTE ? . , D~ana Cordray, IMCA, Clerk Tre surer D~te ~ / '~ Fr' r,,lK E. IRISH I!'qC Mechanical Contractor P, O. Box 11108 625 East 11 th Street Indianapolis, Indiana 46201 Telephone: (317) 636-2337 FAX: (317) 687-2206 To: CARMEL CIVIC SQUARE BUILDING CORP. ATTN: DAVE BRANDT One Civic Square Carmel, Indiana 46032 PROPOSAL H V A C INSPECTION CARMEL CITY BUILDINGS ~o.,: 571 - 2488 o..: ~FAX 571 - 2409 9/19/1997 Furnish labor and miscellaneous material to ~rovide seasonal maintenance on heating and cooling systems at the facilities listed below. Four (4) visits per year wilt be scheduled - - two for heating / two for cooling. All pertinent items will be inspected - heat exchangers, safeties, refrigerant charge, etc. Customer will provide and replace air filters. Building #11 First Avenue Building #15 First Avenue Building #30 West Main Customer will be billed twice yearly ($548.00/each invoice). Contract will automatically renew, unless cancelled by either party thirty days prior to expiration date. TWENTY-FOUR SERVICE INFORMATION WILL BE DISPLAYED ON EQUIPMENT. HOUR t WE PROPOSE hereby to ~rnlsh matert~ and labor -- complete in accordance with the~ specifications. ~r the sum DE ONE THOUSAND NINETY - SIX AND NO / 100 YEARLY dollam(S 1,096.00 NET THIRTY (30) DAYS. ,,,,,,..,,,,,.,....,,,..,...,..,, .... ,,.E. ourcm,r,L~nerh,,.ar~fl~.tornado. andolhernn-ps~umuruut~OurworkesamrullyN~E:ThIsp [ y ~raw ervlce Department c,~r~ by Workmen's U m ~n~ o ~ r~ 'e by us if no accep ed w h n 3 0 days. )ACCE~CE OF PROPOS~ -- The prices. specff(cations and conditions are ~tisfacto~ and are hereby accepted. You a~ authorized to do the work as specified. Payment will be made ~ outlln~ above. Signature Date SIgnature. Date EXHIBIT A page I of 15 F NK E. IRISH INC PROPOSAL Mechanical Contractor P-ge .o. 1 or 1 P.O. BOx 11108 625 East 11th Street Indianapolis, Indiana 46201 H V A C INSPECTION Telephone: (317) 636-2337 FAX: (317) 687-2206 CARMEL FIRE STATIONS To: CARMEL CIVIC SQUARE ~)UILDING CORP. ATTN: DAVE BRANDT One Civic Square ,,o,,: 571 - 2488 Carmel, Indiana 46032 ~FAX 571 - 2409 9/19/1997 We hereby submit spect~catlons and esttfnates for: Furnish labor and miscellaneous material to provide seasonal maintenance on heating and cooling systems at the Fire Stations listed below. Four (4) visits per year w~]l be scheduled - two for heating / two for cooling. All pertinent items will be inspected - heat exchangers, safeties, refrigerant charge, etc. Customer will provide and replace air filters. Station #1 Station #2 Station #3 Station #4 Customer will be billed quarterly ($743.75/each inspection). Contract will automatically renew, unless cancelled by either party thirty days prior to expiration date. TWENTY-FOUR SERVICE INFORMATION WILL BE DISPLAYED ON EQUIPMENT. HOUR TWO THOUSAND NINE HUNDRED SEVENTY - FIVE AND NO / 100 YEARLY dollars(8 2,975.00 NET THIRTY (30) DAYS. 2 Date EXHIBIT A Damp ? ~ 1~ ...... FR41'qK E. IRISH INC PROPOSAL Mechanical Contractor P.O. Box 11108 625 East 11th Street Indianapolis, Indiana 46201 Telephone: (317) 636-2337 FAX: (317) 687-2206 To: CARNEL CIVIC SQUARE BUILDING CORP. ATTN: DAVE BRANDT One Civic Square ,,o,~: 571 - 2488 Carmel, Indiana 46032 ~.FAX 571 - 2409 ~,¢e No. 1 or 1 P~- H v A C INSPECTION CARMEL CIVIC CENTER 10/02/1997 Y / Weherebysubmllspe:lflcationsandesl. lmates~or: Furnish labor and miscellaneous material to provide seasonal maintenance on heating and cooling systems at the Carmel Civic Center. Four (4) visits per year will be scheduled ~ two for heating / two for cooling. All pertinent items will be inspected - heat exchangers, safeties, refrigerant charge, etc. Customer will provide and replace air filters. Customer will be billed twice yearly ($796.00/each invoice). Contract will automatically renew, unless cancelled by either party thirty days prior to expiration date. TWENTY-FOUR HOURS SERVICE INFORMATION WILL BE DISPLAYED ON EQUIPMENT. · / WI~ PROPOSI~ hereby to furnish material and labor -- complete in accordance with these specifications, For the sum of: THREE THOUSAND ONE HUNDRED EIGHTY - FOUR AND NO / 100 dollarsiS 3,184.00 Payable as Ibllows: NET THIRTY (30) DAYS. ,~.. ~,..,. ,.. ,..,,.,,,.- a ~...,,..,. ,...,..,.,,, ,,~,,, .,.,k,....,...~,,,. o, ~y. ~o.. E SHAW, Serv ice Department NOTE: This proposal may b~ wRhdtawn C ACC~C~ OF PROBOS~ -- The prlc~s, specfflca[ions and conditions are ~tisracto~ and are hereby acceptS. You are authorized to do the work a~ specified. Payment wfil ~ made as outlined above. Slgnatur~ Date Signalum Date EXRIBIT A na~e ~ aF 1~ FR4NK E. IRISH II"qC, PROPOSAL Mechanical Contractor F~geNo..__.L._lor 1 P.O. Box 11108 625 East 11th Street fjo..,,.~:,.o -'~ Indianapolis, Indiana46201 H V A C INSPECTION Telephone: (317) 636-2337 FAX: (317) 687-2206 CARMEL POLICE DEPARTMENT To: CARMEL POLICE DEPARTMENT ATTN: DAVE BRANDT One Civic Square ~.o~,: 571 - 2488 Carmel. Indiana 46032 ,,FAX 571 - 2409 10/02/1997 ~We hereby submit specifications and estimates For:. Furnish labor and miscellaneous material to provide seasonal maintenance on heating and cooling systems at the Carmel Police Department. Four (4) visits per year will be scheduled - two for heating / two for cooling. All pertinent items will be inspected - heat exchangers, safeties, refrigerant charge. etc. Customer will provide and replace air filters. Customer will be billed twice yearly ($1,050.O0/each invoice). Contract will automatically renew. unless cancelled by either party thirty days prior to expiration date. TWENTY-FOUR HOURS SERVICE INFORMATION WILL BE DISPLAYED ON EQUIPMENT. PROPOSE hereby to ~rnish material and labor -- complete in accordance with these sp~i~cations. mr the sum oE FOUR THOUSAND TWO HUNDRED AND NO / 100 dollam(8 4,200,00 NET THIRTY (30) DAYS. ~,~,, ,.,,~,. ~m ~ ~.~ .,,,~d ,,.ly ,,,,,,, ~.,., o.l~..,,. ~,, ~',,,...,, ~,.. ~h~,~ o~rDUAa~E SHAW Serv ice Department /ACCE~CE OF PROPOS~ -- The prices. specifk'ations and conditions are ~tisfacto~ and are hereby accepted. You are authorized to do [ the work as specified. Payment will be made as outlined above. ~BZT A page 4 of 15 EXHIBIT A page 5 of 15 Carmel Civic Center City Hall & Police Station Cannel, Indiana HVAC SERVICE CONTRACT Equipment Summary 'APPENDIX 2" WORK CODE E,I E, I E,I E,F,I E,I Et I E,I E,I E,I E,I OUANTr~Y 1 2 ! 2 2 1 2 1 39 9 2 POLICE STATION TAG EB-1 UH-1, -2 CUH-I MU-I, -2 P-l, -2 CP-1 CT-I, -2 WH-I 101-116 201-216 301-307 EF-1, -9 CU-1, -2 DESCRIPTION Brasch #105LW48043 105 KW, 480V- 3-60HZ Electric Boiler Modine Unit Heaters #HES0 5 KW, 460V-3-60HZ Q-Mark CUC-RFF-1600-6KW-480V Env. Technologies, UFC-2500 & UFC- 2000. 21 KW & 15 KW, 460V-3-601[Z Loop Water Pumps, Bell & Gossett End Suction Centrifugal Pumps, 15 HP, 460V-3-60HZ Marathon Electric CC Pumps, 1/20 lIP, iISV-I-60HZ Evapco LSWA-2002 Cooling Tower, 480V-3-60HZ Lochinvar Water Heater #240-MP-36, 36 KW, 480V-3-60HZ Enercon Water Source Heat Pumps Exhaust Fans Water Cooled Condensing Unit, Copeland Model W2WH-0500 Stons- 480V-3-60HZ EXHIBIT A page 6 of 15 Cannel Civic Center Equipment Sunmary Page Two CITY HALL WORK CODE OUANTITY TAG E, F, I 4 AHU-I, 4 E,I 2 RF-I&-2 E, I 13 " EF-I, -13 E, I I CH=I E, I I ACC-1 E, I 2 P-I &-2 E,I 2 UH-I&-2 E, I 4 WH-1, 4 E, I 7 CUH-1, -7 E, F, I 49 W101-118 W201-209 VV301-322 E,I 1 DESCRIPTION Air Handlem with Electric Heating Coils AHU Return Fan RF-I, RF-2 Exhaust Fans Carrier Chiller, 3-stage Air Cooled Condenser Chilled Water Pumps, 5 HP, 460V-3- 60HZ Unit Heaters, 5 KW, 460V-3-60HZ Water Heaters Cabinet Unit Heaters VAV Boxes with heating coils and filters Expansion Tank for ChillM Water System Air Filter Schedule Ouantity Equipment Filters Chanaes/vr. Total 4 Air Handlers 6 - 12 x 24 x 4 pleated 3 18 12 - 24 x 24 x 4 pleated 3 36 2 Make-Up Air Handlers 4 - 20 x 25 x 2 pleated 3 12 * Each filter has 2" throw away pre-~lter that must be replaced, also. NOTE: Filter changes on VAV boxes, heat pumps and cabinet unit heaters will be performed 'by the Buyer's own staff and shall not be included in this contract. EXHIBIT A page 7 of 15 Camel Civic Center HVAC Service Contract Page Three Equipment Services E: All of the above plus an oil analysis and calibration of all operating controls; Meg-ohm compressors and condenser fan motors to ground. Exercise unloaders. Condenser I: Check arid verify proper operation of controls, motor and electrical; lubricate; fully clean unit; replace belts as necessary. Check for refrigerant leaks, verify operation of all (6) stages of head pressure control system fan control. Buyer's own forces will clean coils and clean debris from unit. As above. Air Handler I: Check and verify proper operation of fan and motor; lubricate and replace belts as necessary; clean coils and dampers; check electrical operation. Check cooling coils and mixing valves. E: As above, plus verification of damper actuation. VAV boxes Verify .integrity of ductwork and iniet/outlet connections; check for proper damper operation; lubricate and check for proper operation; clean. E: As above. Duct Heaters I: E: Check wiring, check continuity and current draw on all elements, inspect safety controls All the above, plus exercise and field check the operation of all safety controls and interlocks. EXHIBIT A page 8 of 15 Camel Civic Center HVAC Service Contract Page Four Eouinment Services Expansion Tank Hallway and Vestibule Cabinet Unit Heaters I: Check that valves are open to tank, check tank for leaks, check for proper air charge I: Lubricate motors, inspect wiring, check controls. E: All the above, plus calibrate controls and exercise all safeties. NOTES: 1. Water treatment is included for the closed loop system as well as the cooling towers; analysis and chemicals for the closed loop system are to be provided. Bi-monthly water treatment checks will be included per the schedule in Appendix l, for the cooling towers and closed loop networks. Reports from each inspection and evaluation visit will be submitted to the Buyer within 5 working days after technician's visit. An allowance shall be included to provide some trouble-shooting assistance (as required) with the four (4) Graham #1575 AC Frequency Drives. These units were out of warranty after March 1993. All Johnson Controls instrumentation/controls are fully excluded from Sellers responsibility. cc: 932404tm.doc EXHIBIT A page 9 of 15 'APPENDIX 3" Equipment Cannel Civic Center City Hall & Police Station Carreel, Indiana HVAC SERVICE CONTRACT SERVICE DETAIL Services Electric Boiler & Water Heaters I: E: Check wiring, controls and safety devices; check relief valve; blow-down and remove sediment; temperature control check; perform electrode check for continuity, measure current draw, check for leaks. All of the above, plus full manual unit flush and piping check. Unit Heaters I: Check wiring, controls and safety devices; clean fhn and lubricate; measure current draw; clear air distributors; check temperature. All of the above plus check thermostat calibration and motor integrity. Pumps I: E: Check packing or mechanical seal; lubricate bearings and/or coupling as required; check piping integrity; inspect wiring and starter; measure operating amps; note operating pressures; verify flow. Clean strainers. All of the above, plus thorough cleaning of windings and couplings; verify gauge accuracics by use of dead load tester. Check and record suction and discharge pressures. Exhibit A page 10 of 15 Cannel Civic Center HVAC Service Contract Page Two Equipment Services Heat Pumps I: E: Check unit operation and verify temperatures and pressures are within specs; lubricate bearings, dampers and blower motors; inspect wiring and starter; measure operating drops; verify controls operation; verify refrigerant charge; note and record all pressures; check reversing valve. Clean condensate pan, drains and P-traps. All of the above, plus complete cleaning of all coils and motor windings; change oil as required. Cooling Towers I: Full inspection of unit for scale build-up, corrosion or fouling; check spray nozzles, drain system; heaters; verify controls operation; clean sump; check belts; lubricate; check water treatment; drain and wiaterize per schedule, check spray pump operation. All of the above plus clean fans, test all contrt~l limits and inspect all control limits and inspect all flow channels; clean unit as required. Exhaust Fans I: Verify proper operation, clean fan and fully lubricate; checkelectrical; verify integrity of electrical service. E: As above. Chillers & Compressors I; Check and verify controls operation, valves and oil temperature control; lubricate; inspect coupling; verify oil level and refrigerant charge; note at[ critical pressures. Check compressor oil levels, check waterside pressure differentials, check sight glasses, crankcase heaters. Cheek for reffigerant leaks, check unloaders, log operating conditions. EXHIBIT A page 11 of 15 O0 O0 O0 mo Oo ::l.=t. 0 m ~ ~8 ~8 0 .,n.~ ;o 0 0 o_.. 0 EXHIBIT A page 12 of 15 LIST Of MAINTAINED EQUIPMENT BUILDING Station ff2 QTY. SYSTEM COMPONENT(S) 1 Split System #1 1 Furnace 1 Air Conditioner AGREEMENT NO. PAGE 2 OF 4 RATING MODEL TON/HP ' LOCATION MANUFACTURER Janitrol GDRI-100-4 loo,oo BTU Janitrol CE36-1GB 3 Ton Split System f2 I Furnace Janitrol GDPI100-4 loo,oo0 BTU 1 Air Conditioner Janitrol CE36-1GB 3 Ton 1 Unit Heater 2 Thermostats Reznor Bay Area Services provided to the components listed above are governed by the terms and conditions within this agreement numbered above. EXHIBIT A pare 13 of 15 · LIST OF MAINTAINED EQUIPMENT AGREEMENT NO. BUILDING Station #3 PAGE 3 OF 4 RATING OTY. SYSTEM COMPONENT(S) MANUFACTURER MODEL TON/HP LOCATION I Split System #1 I Furnace Lennox G10R23-11-2 1 lo,0o0 BTU 1 Air Conditioner Janitrol CE36-16B 3 Ton Split System ~ 1 Furnace Lennox G10R23-110-2 110,000BTU 1 Air Conditioner Janitrol CE36-16B 3 Ton 2 Unit Heaters Bryant Bay Area 2 Thermostats Services provided to the components listed above are govemed by the terms and conditions within this agreement numbered above. EXHIBIT A page 14 of 15 ?~~~~~~~~~~:-. ~.IST OF MAINTAINED EQUIPMENT AGREEMENT NO. BUILDING Station #4 PAGE 4 OF RATING QTY. SYSTEM COMPONENT(S) MANUFACTURER MODEL TON/HP LOCATION 1 Split System #1 1 Furnace Carrier 58LS900510 90,000 BTU 1 Air Conditioner Carder 38GS036350 3 Ton Split System #2 1 Furnace Carrier 58LS900510 90,000 BTU 1 Air Conditioner Carrier 38GS036350 3 Ton 2 Unit Heaters Reznor Bay Area 2 Thermostats Services provided to the components listed above are governed by the terms and conditions within this agreement numbered above. EXHIBIT A page 15 of 15