Loading...
c-800 misc details2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com Structure #: Drawn By: Scale: Date: Rvwed Rvw. Date U.S. Patent No. 6524473 and other Patent Pending Aqua-Swirl XCelerator As Shown OFlores Aqua-Swirl Stormwater Treatment System Standard Detail 7/22/2020 XC-5 CCW STD XC-5 STD Aqua-Swirl Polymer Coated Steel (PCS) Stormwater Treatment System 12 in[305 mm] Manhole Frame & Cover Detail For Non-Traffic Areas Only NTS 48 in [1219 mm] Min. Gravel Backfill Concrete Wrap Compressible Expansion Joint Material to a minimum 1/2-inch [13 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Riser Soil Cover Frame 1/2 in [13 mm] 1/2 in [13 mm] Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Backfill (90% Proctor Density) 8 in [203 mm] 4 1/2 in[114 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Manhole Frame & Cover Detail For Traffic Loading Areas NTS Cover Frame 48 in[1219 mm] Min. Backfill (90% Proctor Density) 3,000 psi [20 MPa](min) Concrete #4 [13 mm] Rebar @ 6 in [152 mm] Each Way 30 in [762 mm] Riser 1/2 in[13 mm] 4 1/2 in[114 mm] 14 in [356 mm] 1/2 in [13 mm] Thick Expansion Joint Material If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1/2-inch [13 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Please see accompanied Aqua-Swirl specification notes. See Site Plan for actual System orientation. Approximate dry (pick) weight: 2200 lbs [1000 kg]. Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) Backfill Bedding Undisturbed soil 18 in [457 mm] 6 in [152 mm] 1 1 As an alternative, 42 in [1067 mm] diameter, HS-20/25 rated precast concrete rings may be substituted. 14 in [356 mm] thickness must be maintained. XC-5 inlet/outlet pipe size ranges up to 30 in [762 mm]. XC-5 chamber height may vary up to 116 in [2946 mm], depending on inlet/outlet pipe size. Orientation may vary from a minimum of 90° to a maximum of 180°. Clockwise or counterclockwise orientation as needed. 2 3 3 2 Plan View SCALE 1:40 78 in [1981 mm] 78 in [1981 mm] n30 in [762 mm]2 Octagonal Base Plate Ø66 in [Ø168 mm] Elevation View SCALE 1:40 116 in [2946 mm] Varies Varies 5 MH Frame [127 mm] n30 in [762 mm] Band Coupler by Manufacturer. (as needed)Riser Manhole Frame and Cover by Manufacturer. (See Details) Rim elevations to match finish grade. 68 in [1727 mm] Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. 4 4 el. Varies Inlet/Outlet Invert el. Varies el. Varies Grade (Rim) el. Varies n66 in [1676 mm] Projected View SCALE 1:70 Optional inlet orientations available (See note 4) n30 in [762 mm] 180° C-800CONSTRUCTIONNOT FOR-#####2021-10-29CONTACT(YYYY-MM-DD)CONSULTANTTITLE: DRAWING NO.(YYYY-MM-DD)DATEREV.DESCRIPTIONPROJECT:DATETITLE:CERTIFIED BY:CONSULTANTJOB NUMBERSHEET OFTELEPHONE:LAUTH GROUP, INC.PROJECT:CONTACT:PROJECT NUMBER:STATE NUMBER:E-MAIL:FAX:1ST ON MAINOVERALL DEVELOPMENT41 N RANGELINE RD & 10 E MAIN STCARMEL, INDIANA 460321ST ON MAINKEN STROKE317.848.6500317.848.6511kstroke@lauth.net12021.11.19MODIFICATIONS PER CLIENT COMMENTSDEVELOPMENT CONSULTANTSTRANSPORTATION &BEECH GROVE, IN 46107115 N. 17th AVE.(317) 780-1555CROSSROADENGINEERS.COMPRELIMINARY22022.01.21MODIFICATIONS PER CLIENT AND CITY COMMENTS32022.02.11MODIFICATIONS PER CLIENT AND CITY COMMENTS42022.03.01MODIFICATIONS PER CARMEL FD COMMENTS52022.03.09MODIFICATIONS PER CARMEL FD COMMENTS62022.03.29MODIFICATIONS PER CITY COMMENTS72022.04.08MODIFICATIONS PER CLIENT AND CITY COMMENTS82022.04.18ADDED MFPG & MLAG GRADES PER CITY COMMENTS92022.05.09MODIFICATIONS PER CLIENT AND CITY COMMENTSRIGID PIPE BEDDING DETAIL RCP AND VCP PIPE PVC AND HDPE PIPE FLEXIBLE PIPE BEDDING DETAIL MISCELLANIOUS DETAILSMISCELLANIOUS DETAILS A PART #GRATE OPTIONS NYLOPLAST DRAIN BASIN TYPE 'C' STORM MANHOLE MULTIPLE BICYCLE RACK DETAIL SINGLE BICYCLE RACK