Loading...
116th & Range Line Lighting Markup116th Street Range Line Rd.L in e "PR -S1A "Line "PR-RL1"35Westfield Blvd.App. Exist. R/W App. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/WApp. Exist. R/W App. Exist. R/W App. P.L.App. Exist. R/W 106+95 "PR-RL1", 42.5' LT. Luminaire No. 3 106+50 "PR-RL1", 37.1' RT. Luminaire No. 5 36+95 "PR-S1A", 43.9' RT. Luminaire No. 6 37+52 "PR-S1A", 33.0' LT. Luminaire No. 7 37+23 "PR-S1A", 64.0' LT. Service Point, "A" Type II (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole 34+65 "PR-S1A", 34.3' RT. Luminaire No. 2 R/W R/W& R/WApp. P.L.App. P.L. & R/W App. Exist. R/W R/W P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" =R/W 37+34 "PR-S1A", 35.4' RT. Handhole, Type B the Property of The Carmel Street Department. All Removed Decorative Light Poles to remain NOTE: 109+23 "PR-RL1", 31.7' LT. Luminaire No. 10 109+65 "PR-RL1", 35.5' RT. Luminaire No. 11 105+92 "PR-RL1", 35.5' LT. Luminaire No. 4 105+90 "PR-RL1", 33.5' LT. Comm. Handhole, Type A 35+02 "PR-S1A", 39.2' RT. Comm. Handhole, Type A 36+92 "PR-S1A", 73.0' LT. Comm. Handhole, Type C App. P.L. & R/W(To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole 35+05 "PR-S1A", 40.9' LT. Comm. Handhole, Type B 39+47 "PR-S1A", 43.0' LT. Comm. Handhole, Type A 33+20 "PR-S1A", 35.4' LT. Comm. Handhole, Type A 37+08 "PR-S1A", 40.0' RT. Comm. Handhole, Type B 108+64 "PR-RL1", 46.8' LT. Comm. Handhole, Type B Connect to Prop. Circuit) (To Remain in Place & Exist. Decorative Light Pole 107+01 "PR-RL1", 42.9' LT. Comm. Handhole, Type A 35+29 "PR-S1A", 56.6' RT. Handhole, Type B 33+51 "PR-S1A", 34.0' RT. Luminaire No. 1 35+24 "PR-S1A", 46.6' LT. Luminaire No. 8 108+67.6 "PR-RL1", 43.8' RT. (Exist. Traffic Pole Location) Luminaire No. 9 (To Remain) Exist. Light Pole R/W R/W R/W LD LDLD LD LD EM EME GM W W W W W W W W W W W W T T T H H H H H H H H H H CC-TR C WV WV CC-TR T H WV C WV H T H G H H H T G PF Lighting Circuit Number Service Point A-1 Controller Box (Lighting & Irrigation) (See Carmel Standard Drawings) Handhole (Type as Shown) LEGEND on New Pole w/ 8' Mast Arm and Deco Base (See Carmel Standard Drawings) Proposed 152 W LED Luminaire (2) 4-1C No. 4 CU Conductor in Plastic Duct in Trench (2) 4-1C No. 4 CU Conductor in 3" PVC Schedule 80 Conduit on New 15' Pole and Deco Base (See Carmel Standard Drawings) Proposed 70 W LED Luminaire 1x 4-in. Conduit, PVC, Schedule 40 & 1x 4-in. Conduit, PVC, Schedule 40 with Innerducts (See Carmel Standard Drawings) 1x 4-in. Conduit, PVC, Schedule 80 & 1x 4-in. Conduit, PVC, Schedule 80 with Innerducts (See Carmel Standard Drawings) EMS RJC HRS HRS 1" = 20' N/A 116th ST. AND RANGE LINE RD. LIGHTING DETAILS BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 53 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.LT.01.dgn5/24/2021 09:44:02 AMjhofmanIndiana_Shade.tblIndy-Pdf.pltcfgCITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REENIGNE LANOISS EFORPSTATE OF HAHS .R KIDRAH 11400180